Removal and Replacement Procedures 2-45 To remove a hot-pluggable fan from the server: CAUTION: Never remove both hot-pluggable fans while the server is powered up. Overheating and damage to hardware could result. If the appropriate Compaq software drivers are installed, the operating system software will initiate a power shutdown in the event of overheating. 1. Perform the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Open the top access panel. See "Top Access Panel" earlier in this chapter. 3. Press in the locking latches and remove the failed hot-pluggable fan (either 1 or 2) from of the module . 2 1 Figure 2-37. Removing a hot-pluggable fan Reverse steps 1 through 3 to replace a hot-pluggable fan.
Removal and Replacement Procedures
2-45
To remove a hot-pluggable fan from the server:
CAUTION:
Never remove both hot-pluggable fans while the server is powered up. Overheating
and damage to hardware could result. If the appropriate Compaq software drivers are installed,
the operating system software will initiate a power shutdown in the event of overheating.
1.
Perform the preparation procedures. See
“
Preparation Procedures
”
earlier in this chapter.
2.
Open the top access panel. See
“
Top Access Panel
”
earlier in this chapter.
3.
Press in the locking latches
and remove the failed hot-pluggable fan (either 1 or 2) from
of the module
.
1
2
Figure 2-37.
Removing a hot-pluggable fan
Reverse steps 1 through 3 to replace a hot-pluggable fan.