Dell Force10 C300 Quick Start Guide - Page 20
Specifications, Chassis Physical Design, Environmental Parameters, AC Power Requirements
View all Dell Force10 C300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Specifications Chassis Physical Design Parameter C150 Specifications C300 Specifications Height 15.7 inches (39.88 cm) 22.7 inches (57.66 cm) Width 17.5 inches (44.45 cm) 17.4 inches (37.58 cm) Depth 15.3 inches (38.86 cm) 14.4 inches (44.20 cm) Chassis weight 38 lbs (17.24 kg) with factory 55 lbs (24.95 kg) with factory installed components installed components 86.63 lbs (39.29 kg) fully loaded 152.27 lbs (69.07 kg) fully loaded Environmental Parameters Parameter C150 Specifications Temperature 41° to 104°F (5°C to 40°C) (storage temperature) Maximum thermal 24,566 BTU/hour (for output 100/120V and 200/240V) Relative humidity 5 to 95% (non-condensing) C300 Specifications 41° to 104°F (5°C to 40°C) (storage temperature) 4095 BTU/hour (for 100/120V and 200/240V) 5 to 95% (non-condensing) AC Power Requirements Parameter C150 Specifications Nominal input voltage 100 - 240 V 50/60 Hz Maximum AC Power 14 A @ 100 V per AC Power Supply Input Current Supply (Based on 1200 W 12 A @ 120 V per AC Power output for 100/120 V Supply and 200/240 V lines.) 7 A @ 200 V per AC Power Supply 6 A @ 240 V per AC Power Supply Maximum System Power Input 4.5 KVA @ 100/120 V 4.4 KVA @ 200/240 V C300 Specifications 100-240 VAC 50/60 Hz 14 A @ 100 V per AC Power Supply 12 A @ 120 VAC per AC Power Supply 7 A @ 200 VAC per AC Power Supply 6 A @ 240 VAC per AC Power Supply 8.7 KVA @ 100/120 V 8.5 KVA @ 200/240 V 18 Installing the Hardware