  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 1
    OptiPlex Micro Plus 7010 Owner's Manual Regulatory Model: D15U Regulatory Type: D15U001 March 2023 Rev. A00
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 2
    use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2023 Dell Inc. or its subsidiaries. All rights reserved. Dell
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 3
    ...20 Video port resolution (GPU-Integrated)...20 External display support (GPU-Integrated)...20 Hardware security...21 Environmental...21 Regulatory instructions...23 Before working inside your computer...23 Safety precautions...24 Electrostatic discharge-ESD protection...24 ESD field service kit
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 4
    Installing the side cover...32 Front bezel...33 Removing the front bezel...33 Installing the front bezel...34 Solid-state drive...35 Removing the M.2 2230 solid-state drive from slot 0 35 Installing the M.2 2230 solid-state drive in slot 0 36 Removing the M.2 2230 solid-state drive from slot 1 37
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 5
    password...92 Deleting or changing an existing system setup password 93 Clearing BIOS (System Setup) and System passwords 93 Chapter 9: Troubleshooting...94 Dell SupportAssist Pre-boot System Performance Check diagnostics 94 Running the SupportAssist Pre-Boot System Performance Check 94 Power
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 6
    Front 1 Views of OptiPlex Micro Plus 7010 1. Power button with diagnostic LED 2. Hard-disk activity light 3. Re-tasking line out/line in audio port 4. Universal audio jack 5. USB 3.2 Gen 2 port with PowerShare 6. USB 3.2 Gen 2x2 Type-C port 6 Views of OptiPlex Micro Plus 7010
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 7
    DisplayPort Alt mode) 3. DC-in cable clip 4. USB 3.2 Gen 1 port with Smart Power On 5. Kensington security-cable slot and padlock ring 6. Power-adapter port 7. Service Tag label 8. Three DisplayPort 1.4a (HBR2) 9. Two USB 3.2 Gen 2 ports 10. RJ45 Ethernet port Views of OptiPlex Micro Plus 7010 7
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 8
    Steps 1. Connect the keyboard and mouse. 2 Set up your computer 2. Connect to your network using a cable, or connect to a wireless network. 8 Set up your computer
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 9
    3. Connect the display. 4. Connect the power cable. Set up your computer 9
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 10
    setup. For more information about installing and configuring Ubuntu, search in the Knowledge Base Resource at www.dell.com/support. For Windows: Follow the on-screen instructions to complete the setup. When setting up, Dell recommends that you: ● Connect to a network for Windows updates. 10 Set
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 11
    If not connected to the internet, create an offline account. ● On the Support and Protection screen, enter your contact details. 7. Locate and use Dell apps from . For more information, see SupportAssist for Home PCs User's Guide at www.dell.com/ serviceabilitytools. Click SupportAssist and then,
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 12
    configuration ordered and manufacturing variability. ● Minimum:1.07 kg (2.36 lb) ● Maximum: 1.31 kg (2.89 lb) Processor The following table lists the details of the processors supported by your OptiPlex Micro Plus 7010. 12 Specifications of OptiPlex Micro Plus 7010
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 13
    Table 3. Processor Description Processor type Option one 13th Generation Intel Core i3-13100 Option two 13th Generation Intel Core i3-13100T Option three 13th Generation Intel Core i5-13400 Option four 13th Generation Intel Core i5-13400T Processor wattage 60 W Processor total core 4 count
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 14
    Table 4. Processor Description Processor type Option five 13th Generation Intel Core i5-13500 Option six 13th Generation Intel Core i5-13500T Option seven 13th Generation Intel Core i5-13600 Option eight 13th Generation Intel Core i5-13600T Processor wattage 65 W Processor total core 14 count
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 15
    UHD Graphics 770 36 MB Intel UHD Graphics 770 36 MB Intel UHD Graphics 770 Chipset The following table lists the details of the chipset supported by your OptiPlex Micro Plus 7010. Table 6. Chipset Description Chipset Values Intel Q670 Processor Intel Core i3/i5/i7/i9 DRAM bus width 64/128
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 16
    x 16 GB, DDR5, 4800 MHz, dual-channel ● 64 GB, 2 x 32 GB, DDR5, 4800 MHz, dual-channel Memory matrix The following table lists the memory configurations supported on your OptiPlex Micro Plus 7010. Table 8. Memory matrix Configuration SO-DIMM1 Slot SO-DIMM2 8 GB DDR5 16 GB DDR5 8 GB 16 GB 16
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 17
    2.1/Displayport 1.4a (HBR3)/VGA/PS2/serial/USB Type-C with DisplayPort Alt mode) (Rear) ● Three DisplayPort 1.4a (HBR2) (Rear) Media-card reader Not supported Power-adapter port One DC-in port with 7.40 mm barrel Security-cable slot ● One Kensington lock slot ● One padlock ring Internal slots
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 18
    Description Option one Model number Realtek RTL8852BE Option two Intel AX211 Transfer rate Up to 1201 Mbps Up to 2400 Mbps Frequency bands supported 2.4 GHz/5 GHz 2.4 GHz/5 GHz/6 GHz Wireless standards ● WiFi 802.11a/b/g ● Wi-Fi 4 (WiFi 802.11n) ● Wi-Fi 5 (WiFi 802.11ac) ● Wi-Fi 6 (WiFi
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 19
    volume controls Speaker output: Average speaker output Peak speaker output Subwoofer output Microphone Values Keyboard shortcut controls 2 W 2.5 W Not supported Not supported Storage This section lists the storage options on your OptiPlex Micro Plus 7010. Table 14. Storage matrix Storage
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 20
    the performance of specific components. GPU-Integrated The following table lists the specifications of the integrated Graphics Processing Unit (GPU) supported by your OptiPlex Micro Plus 7010. Table 17. GPU-Integrated Controller Memory size Processor Intel UHD Graphics 730 Shared system
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 21
    of your OptiPlex Micro Plus 7010. Table 20. Hardware security Hardware security Kensington security-cable slot Padlock ring Chasis lock slot support Chassis intrusion switch Supply chain tamper alerts SafeID including Trusted Platform Module (TPM) 2.0 Smart card keyboard (FIPS) Microsoft 10 Device
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 22
    Regulatory compliance The following table lists the regulatory compliance of your OptiPlex Micro Plus 7010. Table 22. Regulatory compliance Regulatory compliance Product Safety, EMC and Environmental Datasheets Dell Regulatory Compliance Home page Dell and the Environment Operating and storage
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 23
    and the contacts. CAUTION: You should only perform troubleshooting and repairs as authorized or directed by the Dell technical assistance team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. See the safety instructions that is shipped with the product or at
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 24
    taken before performing any disassembly instructions. Observe the following safety potential. This is done through the use of a field service electrostatic discharge (ESD) kit. When connecting a bonding wire may not be obvious, such as intermittent problems or a shortened product life span. As the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 25
    The more difficult type of damage to recognize and troubleshoot is the intermittent (also called latent or "walking between your skin, the ESD mat, and the hardware is known as bonding. Use only Field Service kits with a wrist strap, mat, and bonding wire. Never use wireless wrist straps. Always be
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 26
    parts separate from all insulator parts while performing service and that they use anti-static bags for transporting for a stable base, and point your toes out. 2. Tighten stomach muscles. Abdominal muscles support your spine when you lift, offsetting the force of the load. 3. Lift with your legs
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 27
    ● Phillips screwdriver #0 ● Phillips screwdriver #1 ● Plastic scribe Screw list NOTE: When removing screws from a component, it is recommended to note the screw type, the quantity of screws, and then place them in a screw storage box. This is to ensure that the correct number of screws and correct
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 28
    1. Side cover 3. Fan assembly 5. Speaker 7. System board 9. Wireless card 11. Memory module 28 Working inside your computer 2. Front bezel 4. Heat sink 6. Speaker holder 8. Chassis 10. Processor 12. M.2 2280 solid-state drive
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 29
    NOTE: Dell provides a list of components and their part numbers for the original system configuration purchased. These parts are available according to warranty coverages purchased by the customer. Contact your Dell sales representative for purchase options. Working inside your computer 29
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 30
    5 Removing and installing Customer Replaceable Units (CRUs) The replaceable components in this chapter are Customer Replaceable Units (CRUs). CAUTION: Customers can replace only the Customer Replaceable Units (CRUs) following the safety precautions and replacement procedures. NOTE: The images in
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 31
    Steps 1. Place your computer on its side with the side cover facing up. Removing and installing Customer Replaceable Units (CRUs) 31
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 32
    2. Loosen the thumb-screw (6x32) that secures the side cover to the chassis. 3. Slide and lift the side cover off the chassis. Installing the side cover Prerequisites If you are replacing a component, remove the existing component before performing the installation process. About this task The
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 33
    Steps 1. Place the side cover on the chassis. 2. Align the tabs on the side cover with the slots on the chassis. 3. Slide the side cover into place towards the front of the computer. 4. Tighten the thumb-screw (6x32) that secure the side cover to the chassis. Next steps 1. Follow the procedure in
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 34
    Steps 1. Gently pry and release the front-cover tabs from the top-right, working down sequentially to the bottom-right tab. 2. Swing the front bezel outwards, away from the side cover. 3. Lift the front bezel off the side cover. Installing the front bezel Prerequisites If you are replacing a
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 35
    Steps 1. Insert the right-side front-bezel tabs into the corresponding slots on the side cover. 2. Push the left-side of the front bezel towards the side cover, snapping the tabs into position. Next steps 1. Install the side cover. 2. Follow the procedure in After working inside your computer. Solid
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 36
    The following image(s) indicate the location of the M.2 2230 solid-state drive in slot 0 and provides a visual representation of the removal procedure. Steps 1. Remove the screw (M2x3.5) that secures the M.2 2230 solid-state drive to the system board 2. Slide and lift the M.2 2230 solid-state drive
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 37
    Steps 1. Align the notch on the M.2 2230 solid-state drive with the tab on the solid-state drive slot 0 (M.2 PCIe SSD 0). 2. Slide the M.2 2230 solid-state drive into the solid-state drive slot 0 (M.2 PCIe SSD 0) on the system board. 3. Replace the screw (M2x3.5) that secures the M.2 2230 solid-
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 38
    Steps 1. Remove the screw (M2x3.5) that secures the M.2 2230 solid-state drive to the system board 2. Slide and lift the M.2 2230 solid-state drive off the solid-state drive slot 1 (M.2 PCIe SSD 1) on the system board. Installing the M.2 2230 solid-state drive in slot 1 Prerequisites If you are
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 39
    Steps 1. Align the notch on the M.2 2230 solid-state drive with the tab on the solid-state drive slot 1 (M.2 PCIe SSD 1). 2. Slide the M.2 2230 solid-state drive into the solid-state drive slot 1 (M.2 PCIe SSD 1) on the system board. 3. Replace the screw (M2x3.5) that secures the M.2 2230 solid-
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 40
    Steps 1. Remove the screw (M2x3.5) that secures the M.2 2280 solid-state drive to the system board 2. Slide and lift the M.2 2280 solid-state drive off the solid-state drive slot 0 (M.2 PCIe SSD 0) on the system board. Installing the M.2 2280 solid-state drive in slot 0 Prerequisites If you are
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 41
    Steps 1. Align the notch on the M.2 2280 solid-state drive with the tab on the solid-state drive slot 0 (M.2 PCIe SSD 0). 2. Slide the M.2 2280 solid-state drive into the solid-state drive slot (M.2 PCIe SSD 0) on the system board. 3. Replace the screw (M2x3.5) that secures the M.2 2280 solid-state
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 42
    Steps 1. Remove the screw (M2x3.5) that secures the M.2 2280 solid-state drive to the system board 2. Slide and lift the M.2 2280 solid-state drive off the solid-state drive slot 1 (M.2 PCIe SSD 1) on the system board. Installing the M.2 2280 solid-state drive in slot 1 Prerequisites If you are
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 43
    Steps 1. Align the notch on the M.2 2280 solid-state drive with the tab on the solid-state drive slot 1 (M.2 PCIe SSD 1). 2. Slide the M.2 2280 solid-state drive into solid-state drive slot 1 (M.2 PCIe SSD 1) on the system board. 3. Replace the screw (M2x3.5) that secures the M.2 2280 solid-state
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 44
    Steps 1. Remove the screw mount on the system board. 2. Install the screw mount on the system board. Wireless card Removing the wireless card Prerequisites 1. Follow the procedure in Before working inside your computer. 2. Remove the side cover. About this task The following image(s) indicate the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 45
    Steps 1. Remove the screw (M2x3.5) that secures the wireless-card bracket to the wireless card. 2. Lift the wireless-card bracket off the wireless card. 3. Disconnect the antenna cables from the wireless card. 4. Slide and remove the wireless card from the wireless-card slot (M.2 WLAN). Installing
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 46
    Steps 1. Connect the antenna cables to the wireless card. Table 25. Antenna-cable color scheme Connectors on the wireless card Main Antenna-cable color Silkscreen marking White MAIN Auxiliary Black AUX △ (white triangle) ▲ (black triangle) 2. Place the wireless-card bracket on the wireless
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 47
    Speaker Removing the speaker Prerequisites 1. Follow the procedure in Before working inside your computer. 2. Remove the side cover. About this task The following image(s) indicate the location of the speaker and provides a visual representation of the removal procedure. Steps 1. Disconnect the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 48
    Steps 1. Connect the speaker cable to the system board. 2. Press and hold on the tab that secures the speaker to the system board. 3. Place the speaker on the system board. 4. Release the tab that secures the speaker to the system board. Next steps 1. Install the side cover. 2. Follow the procedure
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 49
    Steps 1. Press and hold the tabs that secures the fan assembly to the system board. 2. Lift the fan assembly off the system board and hold it in place. 3. Flip over the fan assembly. Removing and installing Customer Replaceable Units (CRUs) 49
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 50
    4. Disconnect the fan cable from the system board. 5. Lift the fan off the fan shroud. Installing the fan Prerequisites If you are replacing a component, remove the existing component before performing the installation process. About this task The following image(s) indicate the location of the fan
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 51
    Steps 1. Place the fan on the fan shroud. 2. Align the tabs on the fan with the slots on the fan shroud. 3. Snap the fan into place on the fan shroud. 4. Connect the fan cable to the system board. 5. Flip over the fan assembly. 6. Press and hold the tabs on the fan assembly. 7. Place the fan
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 52
    Steps 1. Push the coin-cell battery-release lever on the coin-cell battery socket to release the coin-cell battery out of the socket. 2. Lift the coin-cell battery from the coin-cell battery socket. Installing the coin-cell battery Prerequisites If you are replacing a component, remove the existing
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 53
    Steps With the positive side (+) facing up, insert the coin-cell battery into the battery socket on the system board and snap the battery into place. Next steps 1. Install the side cover. 2. Follow the procedure in After working inside your computer. Memory Removing the memory Prerequisites 1.
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 54
    Steps 1. Carefully spread apart the securing-clips on each end of the memory-module slot. 2. Grasp the memory module near the securing clip, and then gently ease the memory module out of the memory-module slot. CAUTION: To prevent damage to the memory module, hold the memory module by the edges. Do
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 55
    Steps 1. Ensure that the securing clips are in an open position 2. Align the notch on the memory module with the tab on the memory-module slot. 3. Press down on the memory module until the memory module snaps into position and the securing clip locks in place CAUTION: To prevent damage to the memory
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 56
    technicians only. CAUTION: To avoid any potential damage to the component or loss of data, ensure that an authorized service technician replaces the Field Replaceable Units (FRUs). CAUTION: Dell Technologies recommends that this set of repairs, if needed, to be conducted by trained technical repair
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 57
    Steps 1. In reverse sequential order (3>2>1) loosen the three captive screws that secure the heat sink to the system board. 2. Lift the heat sink off the system board. Installing the heat sink Prerequisites If you are replacing a component, remove the existing component before performing the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 58
    Steps 1. Place the heat sink on the system board and the system board. 2. Align the screw holes on the heat sink with the screw holes on the system board. 3. In sequential order (1>2>3) tighten the three captive screws that secure the heat sink to the system board. Next steps 1. Install the fan. 2.
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 59
    The following images indicate the location of the optional I/O module and provide a visual representation of the removal procedure. Steps 1. Remove the two (M3x3) screws that secure the optional I/O module (HDMI/DP/PS2) or two (M2x5) cross type screws that secure the optional I/O module (VGA/Serial
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 60
    Installing the optional I/O module (HDMI/VGA/DP/Serial/PS2) Prerequisites If you are replacing a component, remove the existing component before performing the installation procedure. About this task NOTE: The optional PS2 module comes with a custom Dell adapter cable that is required to access the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 61
    2. Insert the optional I/O module into its slot from the inside of your computer. 3. Connect the I/O cable to the connector on the system board. 4. Replace the two (M3x3) screws that secure the optional I/O module (HDMI/DP/PS2) or two (M2x5) cross type screws that secure the optional I/O module (VGA
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 62
    Installing the optional Type-C module Prerequisites If you are replacing a component, remove the existing component before performing the installation procedure. About this task The following images indicate the location of the optional Type-C module and provide a visual representation of the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 63
    About this task NOTE: The heat sink may become hot during normal operation. Allow sufficient time for the heat sink to cool before you touch it. NOTE: For maximum cooling of the processor, do not touch the heat transfer areas on the heat sink. The oils in your skin can reduce the heat transfer
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 64
    Steps 1. Ensure that the release lever on the processor socket is fully extended in the open position. NOTE: The pin-1 corner of the processor has a triangle that aligns with the triangle on the pin-1 corner on the processor socket. When the processor is properly seated, all four corners are aligned
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 65
    10. Remove the processor. 11. Remove the optional I/O module (VGA/HDMI/DP/Serial)or the optional Type-C module, whichever applicable. About this task The following images indicate the system board connectors. 1. M.2 WLAN connector 2. M.2 SSD PCIe connector (2230/2280) 3. Coin-cell battery 4.
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 66
    66 Removing and installing Field Replaceable Units (FRUs)
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 67
    Steps 1. Remove the screw (M3x5) that secures the speaker-support bracket to the system board. 2. Lift the speaker-support bracket off the system board. 3. Remove the four screws (M3x5) that secures the system board to the chassis. 4. Remove the three screws (M3x4) that secures
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 68
    1. M.2 WLAN connector 2. M.2 SSD PCIe connector (2230/2280) 3. Coin-cell battery 4. Optional video connector (VGA Port/DisplayPort 1.4a (HBR3)/HDMI 2.1 Port) 5. Optional connector (USB 3.2 Gen 2 Type-C Port) 6. Optional PS/2, serial port connector 7. Processor socket 8. Fan connector 9. Internal
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 69
    Removing and installing Field Replaceable Units (FRUs) 69
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 70
    the chassis. 5. Replace the three screws (M3x4) that secures the system board to the chassis. 6. Place the speaker-support bracket on the system board. 7. Align the screw holes on the speaker-support bracket to the screw holes on the system board. 8. Replace the screw (M3x5) that secures the speaker
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 71
    of the antenna module (black cable) and provides a visual representation of the removal procedure. Steps 1. Remove the antenna cable from the routing guides on the chassis. 2. Loosen the captive screw that secures the antenna module (while cable) to the chassis. 3. Lift the antenna module (black
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 72
    hole on the chassis. 3. Tighten the captive screw that secures the antenna module (black cable) to the chassis. 4. Route the antenna cable through the routing guides on the chassis. Next steps 1. Install the system board NOTE: The system board can be installed with the memory, coin-cell battery, and
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 73
    of the antenna module (white cable) and provides a visual representation of the removal procedure. Steps 1. Remove the antenna cable from the routing guides on the chassis and system board. 2. Remove the screw (M3x3) that secures the antenna module (white cable) to the chassis. 3. Listen the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 74
    chassis. 4. Replace the screw (M3x3) that secures the antenna module (white cable) to the chassis. 5. Route the antenna cable through the routing guides on the chassis and system board. Next steps 1. Install the side cover. 2. Follow the procedure in After working inside your computer. Removing SMA
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 75
    2. Remove the side cover. 3. Remove the wireless card. About this task The following images indicate the location of SMA antenna assembly and provide a visual representation of the removal procedure. NOTE: To upgrade to SMA antenna, the internal antenna (white cable) needs to be removed. Removing
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 76
    Steps 1. Remove the SMA antenna assembly cables from the routing guides on the chassis. 2. Remove the screw (M3x3) that secures the SMA antenna assembly to the chassis. 3. Push the SMA antenna assembly inside from the opening
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 77
    the back view. 6. Replace the screw (M3x3) that secures the SMA antenna assembly to the chassis. 7. Route the SMA antenna assembly cables through the routing guides on the chassis. Removing and installing Field Replaceable Units (FRUs) 77
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 78
    Next steps 1. Install the wireless card. 2. Install the side cover. 3. Follow the procedure in after working inside your computer. 78 Removing and installing Field Replaceable Units (FRUs)
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 79
    details the supported operating systems along with instructions on how to install the drivers. Operating system Your OptiPlex Micro Plus 7010 supports the -bit ● Windows 10 Pro, 64 bit Drivers and downloads When troubleshooting, downloading or installing drivers it is recommended that you read the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 80
    8 BIOS setup CAUTION: Unless you are an expert computer user, do not change the settings in the BIOS Setup program. Certain changes can make your computer work incorrectly. NOTE: Depending on the computer and its installed devices, the items listed in this section may or may not be displayed. NOTE
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 81
    the Asset Tag of the computer. Displays the manufacture date of the computer. Displays the ownership date of the computer. Displays the express service code of the computer. Displays the Ownership Tag of the computer. Displays whether the Signed Firmware Update is enabled on your computer. Displays
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 82
    Table 27. System setup options-System information menu (continued) Overview DIMM 2 Size Displays the DIMM 2 memory size. Devices Information Video Controller Displays the video controller type of the computer. Video Memory Displays the video memory information of the computer. Wi-Fi Device
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 83
    Table 29. System setup options-Integrated Devices menu (continued) Integrated Devices Memory Mapped I/O above 4 Gig Allows 64-bit capable PCI devices to be decoded in above 4 GB address space, freeing up memory resources under 4 GB. By default, the this option is enabled. Audio Enable Audio
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 84
    feature. By default, the HTTPs Boot option is enabled. HTTPs Boot Mode With Auto Mode, the HTTPs Boot extracts Boot URL from the DHCP. With Manual Mode, the HTTPs Boot reads Boot URL from the user-provided data. By default, the Auto Mode option is enabled. 84 BIOS setup
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 85
    (S3) mode in the operating system. By default, the Block Sleep option is disabled. Deep Sleep Control Enable or disable the Deep Sleep mode support. By default, the Disabled option is enabled. Fan Control Override Enable or disable the fan control override feature. By default, the option is
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 86
    default, the option is disabled. Absolute Enable or disable or permanently disable the BIOS module interface of the optional Absolute Persistence Module service from Absolute software. By default, the Enable Absolute option is enabled. UEFI Boot Path Security Controls whether or not the computer
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 87
    Master Password Lockout When enabled, this will disable the master password support. By default, the option is disabled. Allow Non-Admin PSID Revert the value specified by the Auto OS Recovery Threshold setup option and local Service OS does not boot or is not installed. By default, the option is
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 88
    Table 37. System setup options-System Management menu (continued) System Management Wake on LAN/WLAN Enable or disable the computer to power on by special LAN signals when it receives a wakeup signal from the WLAN. By default, the Disabled option is selected. Auto on Time Enable to set the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 89
    additional hardware capabilities that are provided by Intel Trusted Execution Technology. By default, the option is disabled. DMA Protection Enable Pre-Boot DMA support. Controls Pre-Boot DMA protection for both internal and external ports. By default, the option is enabled. Enable OS Kernel DMA
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 90
    .dell.com/support. 2. Click Product support. In the Search support box, enter the Service Tag of your computer, and then click Search. NOTE: If you do not have the Service Tag, use the SupportAssist feature to automatically identify your computer. You can also use the product ID or manually browse
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 91
    you saved the BIOS update file. 8. Double-click the BIOS update file icon and follow the on-screen instructions. For more information, search in the Knowledge Base Resource at www.dell.com/support. Updating the BIOS in Linux and Ubuntu To update the system BIOS on a computer that is installed with
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 92
    : ● USB drive formatted to the FAT32 file system (key does not have to be bootable) ● BIOS executable file that you downloaded from the Dell Support website and copied to the root of the USB drive ● AC power adapter that is connected to the computer ● Functional computer battery to flash the
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 93
    The computer restarts. Clearing BIOS (System Setup) and System passwords About this task To clear the system or BIOS passwords, contact Dell technical support as described at www.dell.com/contactdell. NOTE: For information on how to reset Windows or application passwords, refer to the documentation
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 94
    inform you if tests are completed successfully ● View error messages that inform you of problems encountered during testing NOTE: Some tests for specific devices require user interaction. Always ensure that computer, search in the Knowledge Base Resource at www.dell.com/support. 94 Troubleshooting
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 95
    found ● Flash latest BIOS version but invalid ● If problem persists, replace the system board. Power rail failure ● EC ran into power sequencing failure. ● If problem persists, replace the system board. SBIOS Flash corruption ● Flash corruption detected by SBIOS Troubleshooting 95
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 96
    message ● If problem persists, replace from the Dell Support website to troubleshoot and fix your Guide at www.dell.com/serviceabilitytools. Click SupportAssist and then, click SupportAssist OS Recovery. Real Time Clock-RTC reset The Real Time Clock (RTC) reset function allows you or the service
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 97
    is recommended to create a recovery drive to troubleshoot and fix problems that may occur with Windows. Dell proposes multiple performed. The following procedure provides the instructions on how to conduct a Wi-Fi power cycle: NOTE: Some ISPs (Internet Service Providers) provide a modem/router combo
  • Dell OptiPlex Micro Plus 7010 | Owners Manual - Page 98
    about your computer through videos, manuals and documents. Your Dell computer is uniquely identified by a Service Tag or Express Service Code. To view relevant support resources for your Dell computer, enter the Service Tag or Express Service Code at www.dell.com/support. For more information on
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

OptiPlex Micro Plus 7010
Owner's Manual
Regulatory Model: D15U
Regulatory Type: D15U001
March 2023
Rev. A00