Dell PowerEdge C5230 Dell Systems Hardware Owners Manual - Page 84
Err_invalid_pop_minor_qr_an, Err_mem_test_minor_lockste
View all Dell PowerEdge C5230 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Table 2-15. MRC Fatal Error Code (continued) POST Code Nomenclature Major Code ERR_MEM_TEST_MINOR_ SOFTWARE . ERR_MEM_TEST_MINOR_HARDTW ARE ERR_MEM_TEST_MINOR_LOCKSTE P_MODE ERR_VENDOR_SPECIFIC ERR_DIMM_COMPAT 0ECh 0EDh ERR_MIXED_MEM_TYPE ERR_INVALID_POP ERR_INVALID_POP_MINOR_QR_AN D_3RD_SLOT ERR_INVALID_POP_MINOR_UDIMM _AND_3RD_SLOT ERR_INVALID_POP_MINOR_UNSUPP ORTED_VOLTAGE Code Minor 01h 02h 03h Description Software memtest failure Hardware memtest failed Hardware Memtest failure in Lockstep Channel mode requiring a channel to be disabled. This is a fatal error which requires a reset and calling MRC with a difffernt RAS mode to retry. UDIMMs and RDIMMs are both present DIMM vendor-specific errors 01h Different dimm types are detected installed in the system 02h Violation of population rules 03h The 3rd DIMM slot can not be populated when QR DIMMs are installed 04h UDIMMs and SODIMMs are not supported in the third DIMM slot 05h Unsupported DIMM Voltage 84 Using the System Setup Program