Dell PowerEdge C5230 Dell Systems Hardware Owners Manual - Page 93
Dell PowerEdge C5230 Manual
View all Dell PowerEdge C5230 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Table 2-16. MRC Warning Code Warning Major Minor Code Code Data (DWord) Descriptions 31:16 15:0 31:24 23:16 15:8 7:0 WARN_CLTT_MIN OR_NO_TEMP_ SENSOR 01h NODE CH DIMM X A DIMM without Temp Sensor was found WARN_CLTT_MIN OR_CIRCUIT_TST _FAILED 02h NODE CH DIMM X A DIMM failed Temp Sensor circuit test WARN_THROT_IN 19h SUFFICIENT NODE CH DIMM X Indicates throttling is not sufficient for this DIMM due to MRC calculation. WARN_CLTT_DIM 1Ah M_UNKNOWN NODE CH DIMM X A DIMM of an unknown category is found when looking up a predefined category table (DIMM type, rawcard, heat spreader, planner, etc). Use a default category (category 11 or 27 depending on DIMM type) WARN_DQS_TEST 1Bh X X X X DQS training failure encountered WARN_MEM_TES 1Ch T NODE CH DIMM X Hardware Memtest failed and the DIMM is disabled WARN_CLOSED_P 1Dh AGE _OVERRIDE TBD: not currently in use. Using the System Setup Program 93