Dell PowerEdge C6105 Using the Baseboard Management Controller - Page 10
FTP Server Update, Updating BMC Firmware Through Updating Firmware Command
View all Dell PowerEdge C6105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
FTP Server Update: (Ex: ftp://user:[email protected]/s2gv112.bin) >ipmitool -H -I lanplus -U root -P root raw 0x30 0x03 0x01 0x10 0x03 0x00 0x00 0x00 0x01 0xFF 0x68 0x74 0x74 0x70 0x3A 0x2F 0x2F 0x31 0x39 0x32 0x2E 0x31 0x36 0x38 0x2E 0x31 0x2E 0x31 0x31 0x31 0x2F 0x73 0x32 0x67 0x76 0x31 0x31 0x32 0x2E 0x62 0x69 0x6E ASCII code for URL "http://192.168.1.111/s2gv112.bin" Response: 21 written data length TFTP Server Update: (Ex: tftp://192.168.1.111/s2gv112.bin) >ipmitool -H -I lanplus -U root -P root raw 0x30 0x03 0x01 0x10 0x03 0x00 0x00 0x00 0x01 0xFF 0x74 0x66 0x74 0x70 0x3A 0x2F 0x2F 0x31 0x39 0x32 0x2E 0x31 0x36 0x38 0x2E 0x31 0x2E 0x31 0x31 0x31 0x2F 0x73 0x32 0x67 0x76 0x31 0x31 0x32 0x2E 0x62 0x69 0x6E ASCII code for URL "tftp://192.168.1.111/s2gv112.bin" Response: 21 written data length Updating BMC Firmware Through Updating Firmware Command >ipmitool -H -I lanplus -U root -P root raw 0x08 0x01 0x01 0x80 0x00 Response: 34 firmware update task ID (force update, config) >ipmitool -H -I lanplus -U root -P root raw 0x08 0x01 0x01 0x80 0x01 Response: 34 firmware update task ID (normal update, no config) >ipmitool -H -I lanplus -U root -P root raw 0x08 0x01 0x01 0x00 0x00 Response: 34 firmware update task ID (normal update, config) >ipmitool -H -I lanplus -U root -P root raw 0x08 0x01 0x01 0x00 0x01 Response: 34 firmware update task ID 1 Get Firmware Status. 10