Dell PowerEdge C6105 Using the Baseboard Management Controller - Page 20
Table Temperature Thresholds, Voltage Thresholds
View all Dell PowerEdge C6105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Table 1-4. Table Temperature Thresholds (continued) Temperature Sensor Number UNCT UCT P1_DIMM_TEMP 0x4D 96 98 Chassis_Ambient 0x54 48 50 Outlet_TEMP 0x42 N/A N/A Table 1-5. Voltage Thresholds Voltage Sensor CPU_0_Vcore CPU_1_Vcore DDRP0_Voltage DDRP1_Voltage DDRP0_Voltage (LV) DDRP1_Voltage (LV) P5V P3V3 Sensor Number 0x10 0x11 0x12 0x13 0x12 0x13 0x28 0x15 Normal 1.00V 1.00V 1.5V 1.5V 1.35V 1.35V 5V 3.3V LCT N/A N/A 1.349V 1.349V 1.209V 1.209V 4.472V 2.958V LNCT N/A N/A 1.388V 1.388V 1.248V 1.248V 4.628V 3.062V UNCT N/A N/A 1.599V 1.599V 1.443V 1.443V 5.330V 3.526V UCT N/A N/A 1.646V 1.646V 1.482V 1.482V 5.486V 3.629V Table 1-6. Current Thresholds Current Sensor Sensor LCT LNCT UNCT UCT Number MB_12V_Current 0xCA N/A N/A N/A N/A PSU1_OUT_Current 0x70 N/A N/A N/A N/A PSU2_OUT_Current 0x71 N/A N/A N/A N/A Table 1-7. Fan Thresholds Fan Sensor Sensor Number LCT LNCT UNCT UCT FCB Fan 1 0x6B 1000 1200 N/A N/A FCB Fan 2 0x6C 1000 1200 N/A N/A FCB Fan 3 0x6D 1000 1200 N/A N/A FCB Fan 4 0x6E 1000 1200 N/A N/A 20