Dell PowerEdge C6105 Using the Baseboard Management Controller - Page 46
BMC Version Information, BIOS Firmware Information, Present with ASCII Code : S2G_3A15
View all Dell PowerEdge C6105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
>11 00 00 VLAN is disabled/VLAN ID is zero. 2 Enable and Set VLAN ID : >ipmitool -H -I lanplus -U root -P root raw 0x0C 0x01 0x01 0x14 0x02 0x80 3 Disable VLAN ID : >ipmitool -H -I lanplus -U root -P root raw 0x0C 0x01 0x01 0x14 0x00 0x00 BMC Version Information The BMC firmware version can be obtained by using the IPMI - Get Device ID command. To get the BMC firmware version: >ipmitool -H -I lanplus -U root -P root raw 0x06 0x01 >20 01 01 16 02 bf 4c 1c 00 47 32 11 76 00 00 Version 1.16 BIOS Firmware Information The BIOS firmware version can be obtained by using the IPMI - Get Device ID command. To get the BIOS firmware version: > ipmitool -H -I lanplus -U root -P root raw 0x30 0x1e > 53 32 47 5F 33 41 31 35 00 00 Present with ASCII Code : S2G_3A15 46