Dell PowerEdge C6105 Using the Baseboard Management Controller - Page 45
VLAN Configuration, The VLAN is confiugred through the IPMI Set/Get LAN Configuration
View all Dell PowerEdge C6105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Table 1-37. LAN Commands Command NetFn CMD O/M Set LAN Configuration Transport 01h M Parameters (Note: Parameter 9 and 25 are not supported.) Get LAN Configuration Transport 02h M Parameters (Note: Parameter 9 and 25 are not supported.) Suspend BMC ARP Transport 03h O Get IP/UDP/RMCP Statistics Transport 04h O Supported Yes Yes No No Table 1-38. PEF/PET Alerting Commands Command NetFn CMD O/M Get PEF Capabilities S/E 10h M Arm PEF Postpone Timer S/E 11h M Set PEF Configuration Parameters S/E 12h M Get PEF Configuration Parameters S/E 13h M Set Last Processed Event ID S/E 14h M Get Last Processed Event ID S/E 15h M Alert Immediate S/E 16h M PET Acknowledge S/E 17h M Supported Yes Yes Yes Yes Yes Yes Yes Yes VLAN Configuration The VLAN is confiugred through the IPMI Set/Get LAN Configuration command. To configure the VLAN: 1 Get VLAN ID : >ipmitool -H -I lanplus -U root -P root raw 0x0C 0x02 0x01 0x14 0x00 0x00 45