Dell PowerEdge C6220 II Using the Baseboard Management Controller - Page 54
Table 1-38., Sensory Device Commands NetFn: 04H, Command, NetFn, Supported, Table 1-39., Event
View all Dell PowerEdge C6220 II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Table 1-38. Sensory Device Commands (NetFn: 04H) Command NetFn CMD O/M Get Device SDR Info S/E 20h O Get Device SDR S/E 21h O Reserve Device SDR Repository S/E 22h O Get Sensor Reading Factors S/E 23h O Set Sensor Hysteresis S/E 24h O Get Sensor Hysteresis S/E 25h O Set Sensor Threshold S/E 26h O Get Sensor Threshold S/E 27h O Set Sensor Event Enable S/E 28h O Get Sensor Event Enable S/E 29h O Set Sensor Reading and Event Status S/E 30h O Re-arm Sensor Events S/E 2Ah O Get Sensor Event Status S/E 2Bh O Get Sensor Reading S/E 2Dh M Set Sensor Type S/E 2Eh O Get Sensor Type S/E 2Fh O Supported No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Table 1-39. Event Commands (NetFn: 04H) Command Set Event Receiver Get Event Receiver Platform Event NetFn CMD O/M S/E 00h M S/E 01h M S/E 02h M Supported Yes Yes Yes 54