FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Threshold Settings and Converting Formulas The following table lists the system sensor's threshold settings and formulas for converting the sensor readings. Table 1-49. Threshold Settings and Converting Formulas Sensor Sensor Name The Converting Formula Number Upper non- Upper Upper Lower non- Lower Lower recoverable critical non- recoverable critical non- critical critical Voltage 05h 12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001 D4 CA C1 9C A6 AF 06h 5 V Actual_Reading (Volts) = ((Raw_Data x276) + 100) x 0.0001 D0 C7 BE 9A A3 AC 07h 5 V Standby Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x 0.0001 D0 C7 BE 9A A3 AC 08h 3.3 V Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x 0.0001 BF B7 AE 8D 95 9E 09h 3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x 0.0001 C1 B9 B0 8F 97 A0 60