Dell PowerEdge C6220 II Using the Baseboard Management Controller - Page 55

Table 1-40., SEL Commands NetFn: 04H, Command, NetFn, Supported, Table 1-41., FRU Inventory Device

Page 55 highlights

FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Table 1-40. SEL Commands (NetFn: 04H) Command NetFn CMD O/M Get SEL Info Storage 40h M Get SEL Allocation Info Storage 41h O Reserve SEL Storage 42h O Get SEL Entry Storage 43h M Add SEL Entry Storage 44h M Partial Add SEL Entry Storage 45h M Delete SEL Entry Storage 46h O Clear SEL Storage 47h M Get SEL Time Storage 48h M Set SEL Time Storage 49h M Get Auxiliary Log Status Storage 5Ah O Set Auxiliary Log Status Storage 5Bh O Get SEL Time UTC Offset Storage 5Ch O Set SEL Time UTC Offset Storage 5D O * Support for Partial Add SEL is not required when Add SEL is supported. Table 1-41. FRU Inventory Device Commands (NetFn: 0AH) Command Get FRU Inventory Area Info Read FRU Inventory Data Write FRU Inventory Data NetFn CMD O/M Storage 10h M Storage 11h M Storage 12h M Supported Yes No Yes Yes Yes No* No Yes Yes Yes No No No No Supported Yes Yes Yes 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

55
FILE LOCATION:
D:\Projects\User
Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm
* Support for Partial Add SEL is not required when Add SEL is supported.
Table 1-40.
SEL Commands (NetFn: 04H)
Command
NetFn
CMD
O/M
Supported
Get SEL Info
Storage
40h
M
Yes
Get SEL Allocation Info
Storage
41h
O
No
Reserve SEL
Storage
42h
O
Yes
Get SEL Entry
Storage
43h
M
Yes
Add SEL Entry
Storage
44h
M
Yes
Partial Add SEL Entry
Storage
45h
M
No
*
Delete SEL Entry
Storage
46h
O
No
Clear SEL
Storage
47h
M
Yes
Get SEL Time
Storage
48h
M
Yes
Set SEL Time
Storage
49h
M
Yes
Get Auxiliary Log Status
Storage
5Ah
O
No
Set Auxiliary Log Status
Storage
5Bh
O
No
Get SEL Time UTC Offset
Storage
5Ch
O
No
Set SEL Time UTC Offset
Storage
5D
O
No
Table 1-41.
FRU Inventory Device Commands (NetFn: 0AH)
Command
NetFn
CMD
O/M
Supported
Get FRU Inventory Area Info
Storage
10h
M
Yes
Read FRU Inventory Data
Storage
11h
M
Yes
Write FRU Inventory Data
Storage
12h
M
Yes