Dell PowerEdge C6220 II Using the Baseboard Management Controller - Page 61
The Converting Formula, Sensor Name
View all Dell PowerEdge C6220 II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Table 1-50. Threshold Settings and Converting Formulas (continued) Sensor Sensor Name Number The Converting Formula Upper non- Upper Upper Lower non- Lower Lower recoverable critical non- recoverable critical non- critical critical Temperature 40h MEZZ1 Temp Actual_Reading (degrees C) = Raw_Data - 128 C6 BC B0 8F 97 A0 41h CPU1 Temp Actual_Reading (degrees C) = Raw_Data 5A 50 46 20 25 29 42h CPU2 Temp Actual_Reading (degrees C) = Raw_Data 5A 50 46 20 25 29 43h DIMM ZONE Actual_Reading (degrees C) = Raw_Data 1 Temp 3C 32 28 17 1A 1E 44h DIMM ZONE Actual_Reading (degrees C) = Raw_Data 2 Temp 3C 32 28 17 1A 1E 45h PCH Temp Actual_Reading (degrees C) = Raw_Data 5A 50 46 17 1A 1E 61