Dell PowerEdge M420 Dell PowerEdge M620 Systems Owner's Manual - Page 111

Internal Dual SD Module is not redundant. Insufficient resources. Check SD Card.

Page 111 highlights

Error Code Message Information Action Replace the failed SD card. RFM1202 Message Details Action Internal Dual SD Module redundancy is degraded. Either one of the SD card or both the SD cards are not functioning properly. Replace the failed SD card. RFM1203 Message Details Action Internal Dual SD Module is not redundant. Internal Dual SD Module is not redundant. Install additional SD card and configure for redundancy if redundancy is desired. RFM1205 Message Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations. LCD Message Internal Dual SD Module is not redundant. Insufficient resources. Check SD Card. Details The current operating configuration cannot maintain redundancy. The unit may operate in a degraded state. Action Review this manual and SD card configuration. RFM2001 Message LCD Message Details Action Internal Dual SD Module is absent. Internal Dual SD Module is absent. Check SD Card. The SD card module is not detected or not installed. If unintended, reinstall the SD module. RFM2002 Message Internal Dual SD Module is offline. Details The SD card module is installed but may be improperly installed or configured incorrectly. Action Reinstall the SD module. RFM2004 Message LCD Message Details Action Failure detected on Internal Dual SD Module . Internal Dual SD Module failed. Check SD Card. The SD card module is installed but improperly configured or failed to initialize. Reinstall the SD module and remove and reinstall SD cards. RFM2006 Message Details Action Internal Dual SD Module is write protected. The module is write-protected. Changes may not be written to the media. If unintended, remove the media and disable write protection. SEC0000 Message The chassis is open. 111

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

Error Code
Message Information
Action
Replace the failed SD card.
RFM1202
Message
Internal Dual SD Module redundancy is degraded.
Details
Either one of the SD card or both the SD cards are not functioning properly.
Action
Replace the failed SD card.
RFM1203
Message
Internal Dual SD Module is not redundant.
Details
Internal Dual SD Module is not redundant.
Action
Install additional SD card and configure for redundancy if redundancy is desired.
RFM1205
Message
Internal Dual SD Module is not redundant. Insufficient resources to maintain normal
operations.
LCD Message
Internal Dual SD Module is not redundant. Insufficient resources. Check SD Card.
Details
The current operating configuration cannot maintain redundancy. The unit may operate
in a degraded state.
Action
Review this manual and SD card configuration.
RFM2001
Message
Internal Dual SD Module <
name
> is absent.
LCD Message
Internal Dual SD Module <
name
> is absent. Check SD Card.
Details
The SD card module is not detected or not installed.
Action
If unintended, reinstall the SD module.
RFM2002
Message
Internal Dual SD Module <
name
> is offline.
Details
The SD card module is installed but may be improperly installed or configured incorrectly.
Action
Reinstall the SD module.
RFM2004
Message
Failure detected on Internal Dual SD Module <
name
>.
LCD Message
Internal Dual SD Module <
name
> failed. Check SD Card.
Details
The SD card module is installed but improperly configured or failed to initialize.
Action
Reinstall the SD module and remove and reinstall SD cards.
RFM2006
Message
Internal Dual SD Module <
name
> is write protected.
Details
The module is write-protected.
Changes may not be written to the media.
Action
If unintended, remove the media and disable write protection.
SEC0000
Message
The chassis is open.