Dell PowerEdge M420 Dell PowerEdge M620 Systems Owner's Manual - Page 81
Bay ID, number, Review System Event Log and Operating System Logs. If the issue persists, see
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Error Code Message Information BAT0012 Message The storage battery for disk drive bay has failed. LCD Message Battery for disk drive bay has failed. Check battery. Details Verify the cable connection between the storage battery and the controller. Action Verify the storage battery installation. BAT0014 Message LCD Message Details Action The storage battery for disk drive bay is absent. Battery for disk drive bay is absent. Check battery. Verify the cable connection between the storage battery and the controller. Verify the storage battery installation. BAT0015 Message The battery is low. Details The low battery may impact system performance negatively. Action Recharge the battery if possible. If the problem continues replace the battery. BAT0017 Message The battery has failed. LCD Message The battery has failed. Check battery. Details The battery is either missing, bad, or unable to charge due to thermal issues. Action Check system fans. Replace the battery. BAT0019 Message LCD Message Details Action The battery is absent. The battery is absent. Check battery. The failed or missing battery may reduce system performance. Check system fans. Replace the battery. CBL0006 Message Multiple storage controllers are incorrectly connected to the same backplane . Details Unsupported backplane configuration. Action Check backplane configuration. Reconnect cable. If the issue persists, see Getting Help. CPU0000 Message CPU has an internal error (IERR). LCD Message CPU has an internal error (IERR). Details System event log and OS logs may indicate that the exception is external to the processor. Action Review System Event Log and Operating System Logs. If the issue persists, see Getting Help. 81