Dell PowerEdge M420 Dell PowerEdge M520 Systems Owner's Manual - Page 103
Lost PSU redundancy. Check PSU cables., >. Re-seat PSU.
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 103 highlights
Error Code Message Information PSU0008 Message Power supply voltage rating does not match the system's requirements. Details The system does not support mixed voltage power supplies. Action Install a power supply with the correct voltage rating. PSU0016 Message LCD Message Details Action Power supply is absent. PSU is absent. Check PSU. The supply has been removed or has failed. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. PSU0031 PSU1201 PSU1202 PSU1203 PSU1204 Message Cannot communicate with power supply . LCD Message Cannot communicate with PSU . Re-seat PSU. Details The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded. Action Remove and reinstall the power supply. If the issue persists, see Getting Help. Message Power supply redundancy is lost. Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Check input power. Reinstall the power supply. If the issue persists, see Getting Help. Message Power supply redundancy is degraded. Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost. Action Remove input power and reinstall supply at the next service window. Message The power supplies are not redundant. LCD Message Lost PSU redundancy. Check PSU cables. Details The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. Action Check the event log for power supply failures. Review system configuration and power consumption. Message The power supplies are not redundant. Insufficient resources to maintain normal operations. LCD Message PSU redundancy degraded. Check PSU cables. 103