Dell PowerEdge M420 Dell PowerEdge M520 Systems Owner's Manual - Page 83
> voltage regulator module is outside of range, but it is
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Error Code Message Information 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. CPU0803 Message LCD Message Details Action The power input for CPU voltage regulator module is lost. Lost power input for CPU voltage regulator module. Re-seat module. System performance may be degraded or the system may fail to operate. 1. Turn system off and remove input power for one minute. 2. Reapply input power and turn system on. 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. CPU0804 Message The power input for CPU voltage regulator module is outside of range. LCD Message The power input for CPU voltage regulator module is outside of range. Reseat module. Details System performance may be degraded or the system may fail to operate. Action 1. Turn system off and remove input power for one minute. 2. Reapply input power and turn system on. 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. CPU0805 Message The power input for CPU voltage regulator module is outside of range, but it is attached to the system. Details System performance may be degraded or the system may fail to operate. Action 1. Turn system off and remove input power for one minute. 2. Reapply input power and turn system on. 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. CPU0806 CPU0816 Message CPU voltage regulator module is incorrectly configured. LCD Message CPU voltage regulator module incorrectly configured. Check configuration. Details System performance may be degraded or the system may fail to operate. Action Review this manual for proper configuration and installation procedures. Message LCD Message CPU voltage regulator module is absent. CPU voltage regulator module absent. Check module. 83