Dell PowerEdge M420 Dell PowerEdge M520 Systems Owner's Manual - Page 118
Remove the processor module. Inspect processor socket for bent pins.
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Error Code Message Information 3. If the issue persists, see Getting Help. VLT0102 Message Processor module voltage is greater than the upper warning threshold. LCD Message Processor module voltage is outside of range. Details System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Action 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. VLT0103 Message Processor module voltage is greater than the upper critical threshold. LCD Message Processor module voltage is outside of range. Details System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Action 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. VLT0104 Message Processor module voltage is outside of the allowable range. LCD Message Processor module voltage is outside of range. Details System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Action 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. VLT0200 Message The system board voltage is less than the lower critical threshold. LCD Message System board voltage is outside of range. Details System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in failsafe mode. Action 1. Review system logs for power supply exceptions. 118