Dell PowerEdge M420 Dell PowerEdge M520 Systems Owner's Manual - Page 116
The system inlet temperature is greater than the upper critical threshold.
View all Dell PowerEdge M420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
Error Code Message Information TMP0119 Message The system inlet temperature is less than the lower critical threshold. LCD Message System inlet temperature is outside of range. Details Ambient air temperature is too cool. Action Check the system operating environment. TMP0120 Message LCD Message Details Action The system inlet temperature is greater than the upper warning threshold. System inlet temperature is outside of range. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. TMP0121 Message LCD Message Details Action The system inlet temperature is greater than the upper critical threshold. System inlet temperature is outside of range. Check Fans. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. TMP0122 Message LCD Message Details Action The system inlet temperature is outside of range. System inlet temperature is outside of range. Check Fans. Ambient air temperature is too warm or cool. Check the system operating environment and review event log for fan failures. TMP0100 Message Details Action Disk drive bay temperature is less than the lower warning threshold. Ambient air temperature is too cool. Check the system operating environment. TMP0104 Message LCD Message Details Action Disk drive bay temperature is less than the lower critical threshold. Disk drive bay temperature is outside of range. Check Fans. Ambient air temperature is too cool. Check the system operating environment. TMP0126 Message LCD Message Details Action Disk drive bay temperature is greater than the upper warning threshold. Disk drive bay temperature is outside of range. Check Fans. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. TMP0128 Message Disk drive bay temperature is outside of the allowable range. 116