Dell PowerEdge R740 EMC PowerEdge Servers Troubleshooting Guide - Page 10

Diagnostic indicators, Status LED indicators

Page 10 highlights

2 Diagnostic indicators The diagnostic indicators on the system indicates operation and error status. Topics: • Status LED indicators • System health and system ID indicator codes • iDRAC Quick Sync 2 indicator codes • iDRAC Direct LED indicator codes • NIC indicator codes • Power supply unit indicator codes • Non-redundant power supply unit indicator codes • Hard drive indicator codes • uSATA SSD indicator codes • Internal dual SD module indicator codes Status LED indicators The status LED indicators on the system front panel display error status during system startup. NOTE: No status LED indicators are illuminated when the system is turned off. To start the system, plug it into a working power source and press the power button. NOTE: Status LED indicators are always off and only turn solid amber if any error occurs. Table 2. Status LED indicators Icon Description Condition Corrective action Hard drive indicator The indicator turns solid amber if there is a hard drive error. Check the System Event Log to determine if the hard drive has an error. Run the appropriate Online Diagnostics test. Restart the system and run embedded diagnostics (ePSA). If the hard drives are configured in a RAID array, restart the system and enter the host adapter configuration utility program. Temperature indicator The indicator turns solid amber if the system experiences a thermal error (for example, the ambient temperature is out of range or fan failure). Ensure that none of the following conditions exist: • A cooling fan has been removed or has failed. • System cover, air shroud, EMI filler panel, memory module blank, or back filler bracket is removed. • Ambient temperature is too high. • External airflow is obstructed. If the problem persists, see the Getting help section. Electrical indicator The indicator turns solid amber if the Check the System Event Log or system messages for the system experiences an electrical error specific issue. If it is due to a problem with the PSU, (for example, voltage out of range, or check the LED on the PSU. Reseat the PSU. If the a failed power supply unit (PSU) or problem persists, see the Getting help section. voltage regulator). Memory indicator The indicator turns solid amber if a memory error occurs. Check the System Event Log or system messages for the location of the failed memory. Reseat the memory module. If the problem persists, see the Getting help section. 10 Diagnostic indicators

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

Diagnostic indicators
The diagnostic indicators on the system indicates operation and error status.
Topics:
Status LED indicators
System health and system ID indicator codes
iDRAC Quick Sync 2 indicator codes
iDRAC Direct LED indicator codes
NIC indicator codes
Power supply unit indicator codes
Non-redundant power supply unit indicator codes
Hard drive indicator codes
uSATA SSD indicator codes
Internal dual SD module indicator codes
Status LED indicators
The status LED indicators on the system front panel display error status during system startup.
NOTE:
No status LED indicators are illuminated when the system is turned off. To start the system, plug it into a
working power source and press the power button.
NOTE:
Status LED indicators are always off and only turn solid amber if any error occurs.
Table 2. Status LED indicators
Icon
Description
Condition
Corrective action
Hard drive
indicator
The indicator turns solid amber if
there is a hard drive error.
Check the System Event Log to determine if the hard
drive has an error. Run the appropriate Online Diagnostics
test. Restart the system and run embedded diagnostics
(ePSA). If the hard drives are configured in a RAID array,
restart the system and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if the
system experiences a thermal error
(for example, the ambient
temperature is out of range or fan
failure).
Ensure that none of the following conditions exist:
A cooling fan has been removed or has failed.
System cover, air shroud, EMI filler panel, memory
module blank, or back filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
If the problem persists, see the Getting help section.
Electrical indicator
The indicator turns solid amber if the
system experiences an electrical error
(for example, voltage out of range, or
a failed power supply unit (PSU) or
voltage regulator).
Check the System Event Log or system messages for the
specific issue. If it is due to a problem with the PSU,
check the LED on the PSU. Reseat the PSU. If the
problem persists, see the Getting help section.
Memory indicator
The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages for the
location of the failed memory. Reseat the memory module.
If the problem persists, see the Getting help section.
2
10
Diagnostic indicators