Dell PowerStore 1200T EMC PowerStore Networking Guide for PowerStore T Models - Page 30

Validate the configuration on the Management switch

Page 30 highlights

Management Upstream A Management Upstream B Figure 8. Management switch connection to management upstream switches Table 11. Steps to connect to the Management switch to the management upstream 1 Connect Management switch port 25 to the Management Upstream A. 2 Connect Management switch port 26 to the Management Upstream B. Validate the configuration on the Management switch After you have configured the Management switch, and cabled the switches to your PowerStore T model nodes, validate the switch configuration prior to discovering PowerStore T model. 1. Establish a terminal session to the switch. 2. Validate the interface status. show interface status | grep up Port Eth 1/1/1 Eth 1/1/2 Eth 1/1/25 Eth 1/1/26 Eth 1/1/53 Description Status discoveryWork.. up PowerStoreNod.. up Uplink_Ports up Uplink_Ports up PowerStoreNod.. up 3. Validate the port channel configuration. show port-channel summary Speed 1000M 1000M 100G 100G 1000M Duplex full full full full full Mode Vlan Tagged-Vlans A 100 - A 100 - - - A 100 - Flags: D - Down I - member up but inactive P - member up and active U - Up (port-channel) F - Fallback Activated 30 Configuring Dell PowerSwitch Series for Initial Deployment

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

Management Upstream A
Management Upstream B
Figure 8. Management switch connection to management upstream switches
Table 11. Steps to connect to the Management switch to the management upstream
1
Connect Management switch port 25 to the Management Upstream A.
2
Connect Management switch port 26 to the Management Upstream B.
Validate the configuration on the Management switch
After you have configured the Management switch, and cabled the switches to your PowerStore T model nodes, validate the
switch configuration prior to discovering PowerStore T model.
1.
Establish a terminal session to the switch
.
2.
Validate the interface status.
show interface status | grep up
Port
Description
Status
Speed
Duplex
Mode Vlan Tagged-Vlans
Eth 1/1/1
discoveryWork.. up
1000M
full
A
100
-
Eth 1/1/2
PowerStoreNod.. up
1000M
full
A
100
-
Eth 1/1/25
Uplink_Ports
up
100G
full
-
Eth 1/1/26
Uplink_Ports
up
100G
full
-
Eth 1/1/53
PowerStoreNod.. up
1000M
full
A
100
-
3.
Validate the port channel configuration.
show port-channel summary
Flags:
D - Down
I - member up but inactive
P - member up and active
U - Up (port-channel)
F - Fallback Activated
--------------------------------------------------------------------------------
30