Dell PowerVault 120T DDS4 User Guide - Page 50
Swept Sine 5 to 500 Hz @ 0.5 G Peak .25 Octave/min. 3 axis, 3
View all Dell PowerVault 120T DDS4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
DC 12 V +/-10% 100 mV p-p Maxium (load/unload) 1.6 A Typical 0.3 A Dimensions Internal Height 82.5mm Width 146.0mm Depth 241.6mm External Height 109.0mm Width 211.0mm Depth 296.0mm Environmental Operating Temperature Non-Operating Temperature (mech) Non-Operating Temperature (tape) Operating Humidity Non-Operating Humidity (mech) Non-Operating Humidity (tape) Operating Altitude Operating Dust Operating Vibration Non-Operating Vibration Operating Shock Non-Operating Shock 5C to 40C (T
Dell PowerVault 120T DDS4 Autoloader User's Guide B-3
DC 12 V +/-10%
100 mV p-p
Maxium (load/unload)
1.6 A
Typical
0.3 A
Dimensions
Internal
Height 82.5mm
Width 146.0mm
Depth 241.6mm
External
Height 109.0mm
Width 211.0mm
Depth 296.0mm
Environmental
Operating Temperature
5C to 40C (T<10C/h)
Non-Operating
Temperature (mech)
-40C to 70C (T<C/h)
Non-Operating
Temperature
(tape)
-40C to 45C (T<20C/h)
Operating Humidity
20 to 80% RH , non-condensing,
Maxium wet bulb
temperature = 26C
Non-Operating Humidity
(mech)
5 to 95% RH
(RH <30%/h)
Non-Operating Humidity
(tape)
20 to 80% RH
(RH <30%/h)
Operating Altitude
0 to 4572 meters (0 to 15,000 feet)
Operating Dust
Less than 150 microgram/m3, Based sampling period 24
hours
Operating Vibration
Swept Sine 5 to 500 Hz @ 0.5 G Peak .25 Octave/min. 3 axis, 3
direction
Non-Operating Vibration
Swept Sine 5 to 500 Hz @ 0.75 G Peak .25 Octave/min. 3 axis,
3 direction
Operating Shock
No Data Loss
Half Sine 10 G Peak 11 ms 3 axes, 3 directions
Interval 10 seconds
Non-Operating Shock
No Device Damage
Half Sine 90 G Peak 11 ms 3 axes, 3
directions