Dell S5224F-ON EMC PowerSwitch S5200F-ON Series Installation Guide February 20 - Page 17

Table 3. SFP28 port LEDs-S5232F-ON, S5248F-ON, and S5296F-ON

Page 17 highlights

Table 2. System management Ethernet port LEDs LED Link LED Activity LED Description ● Off-No link ● Solid green-Link operating at a maximum speed, autonegotiated/forced to 1000MBase-T mode ● Solid yellow-Link operating at a lower speed, autonegotiated/forced or 10/100MBase-T mode ● Off-No activity ● Flashing green-Port activity Table 3. SFP28 port LEDs-S5232F-ON, S5248F-ON, and S5296F-ON LED Description Link LED All four LEDs: ● Off-No link ● Solid green-Link operating at maximum speed, 25G ● Solid yellow-Link operating at a lower speed, 10G or 1G ● Flashing green, ~30ms-Port activity operating at maximum speed, 25G port ● Flashing yellow, ~30ms-Port activity operating at lower speed, 10G or 1G port ● Flashing yellow, 1 second on/off-port beacon Activity LED ● Off-No activity ● Flashing green-port activity at maximum speed ● Flashing yellow-port activity at lower speed Table 4. SFP+ port LEDs-S5232F-ON LED Link LED Activity LED Description All four LEDs: ● Off-No link ● Solid green-Link operating at maximum speed, 10G ● Solid yellow-Link operating at a lower speed, 1G ● Flashing green, ~30ms-Port activity operating at maximum speed, 10G port ● Flashing yellow, ~30ms-Port activity operating at lower speed, 1G port ● Flashing yellow, 1 second on/off-port beacon ● Off-No activity ● Flashing green-port activity at maximum speed ● Flashing yellow-port activity at lower speed NOTE: The first QSFP-DD port LED shows 200GbE, 100GbE, 40GbE, and 10GbE mode. All eight QSFP-DD port LEDs show 8x25GbE or 8x10GbE mode. The first and fifth QSFP-DD port LEDs show 2x100GbE mode. The first, second, fifth, and sixth QSFP-DD port LEDs show 2x50GbE mode. The first and second LEDs for the first 2x50GbE port and the fifth and sixth LEDs for the second 2x50GbE port. Table 5. QSFP-DD port LEDs-S5248F-ON LED Description Link/Activity LED-200GbE, 100GbE, 40GbE, or 10GbE mode First LED: ● Off-No link/activity ● Solid green-Port link operating at maximum speed, 200G ● Flashing green-Port activity operating at maximum speed, 200G S5200F-ON Series switch 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Table 2. System management Ethernet port LEDs
LED
Description
Link LED
Off—No link
Solid green—Link operating at a maximum speed,
autonegotiated/forced to 1000MBase-T mode
Solid yellow—Link operating at a lower speed,
autonegotiated/forced or 10/100MBase-T mode
Activity LED
Off—No activity
Flashing green—Port activity
Table 3. SFP28 port LEDs—S5232F-ON, S5248F-ON, and S5296F-ON
LED
Description
Link LED
All four LEDs:
Off—No link
Solid green—Link operating at maximum speed, 25G
Solid yellow—Link operating at a lower speed, 10G or 1G
Flashing green, ~30ms—Port activity operating at
maximum speed, 25G port
Flashing yellow, ~30ms—Port activity operating at lower
speed, 10G or 1G port
Flashing yellow, 1 second on/off—port beacon
Activity LED
Off—No activity
Flashing green—port activity at maximum speed
Flashing yellow—port activity at lower speed
Table 4. SFP+ port LEDs—S5232F-ON
LED
Description
Link LED
All four LEDs:
Off—No link
Solid green—Link operating at maximum speed, 10G
Solid yellow—Link operating at a lower speed, 1G
Flashing green, ~30ms—Port activity operating at
maximum speed, 10G port
Flashing yellow, ~30ms—Port activity operating at lower
speed, 1G port
Flashing yellow, 1 second on/off—port beacon
Activity LED
Off—No activity
Flashing green—port activity at maximum speed
Flashing yellow—port activity at lower speed
NOTE:
The first QSFP-DD port LED shows 200GbE, 100GbE, 40GbE, and 10GbE mode. All eight QSFP-DD port LEDs show
8x25GbE or 8x10GbE mode. The first and fifth QSFP-DD port LEDs show 2x100GbE mode. The first, second, fifth, and sixth
QSFP-DD port LEDs show 2x50GbE mode. The first and second LEDs for the first 2x50GbE port and the fifth and sixth
LEDs for the second 2x50GbE port.
Table 5. QSFP-DD port LEDs—S5248F-ON
LED
Description
Link/Activity LED—200GbE, 100GbE, 40GbE, or 10GbE mode
First LED:
Off—No link/activity
Solid green—Port link operating at maximum speed, 200G
Flashing green—Port activity operating at maximum
speed, 200G
S5200F-ON Series switch
17