Dell S5296F-ON EMC PowerSwitch S5200F-ON Series Setup Guide - Page 18

Two U four-post rack assembly, Four-post rack mount

Page 18 highlights

3. Tighten the two thumb screws and rack screws. To remove the chassis from the rack or cabinet, press in the two side-release bars on the chassis at the same time and slide the chassis forward. Two U four-post rack assembly Due to the chassis weight, the S5296F-ON switch does not support a two-post rack installation; you must install the S5296F-ON in a four-post rack. NOTE: To install the S5212F-ON, see One-half U front-rack installation. To install the S5232F-ON, S5248F-ON, or S5224F-ON switch, see One U ReadyRails installation. To install in a four-post rack, follow the instructions in your rack frame kit. In a four-post rack, the maximum distance between the front and back vertical posts is 36 inches (91.44 cm); the minimum distance is 24 inches (60.96). CAUTION: Use two people, an equipment lift, or pallet jack when lifting or moving the chassis. Install the chassis into the rack before inserting the chassis components. Lift the chassis only from the bottom. Lifting by the chassis shelves or power supply openings might damage the chassis. Four-post rack mount Rack mounting safety considerations NOTE: To prevent bodily injury when mounting or servicing this unit in a rack, take special precautions to ensure that the chassis remains stable. The following guidelines are provided to ensure your safety: • If your chassis is the only unit in the rack, mount it at the bottom of the rack. • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. • If the rack comes with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. • If the chassis ships with blanks, remove the blanks from each slot before lifting the chassis. NOTE: These instructions are a condensed reference. Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before you begin. NOTE: The illustrations in this document are not intended to represent a specific switch. • Rack loading-Overloading or uneven loading of racks may result in shelf or rack failure, possibly damaging the equipment and causing personal injury. Stabilize racks in a permanent location before loading begins. Mount the components starting at the bottom of the rack, then work to the top. Do not exceed your rack's load rating. • Power considerations-Connect only to the power source specified on the unit. When you install multiple electrical components in a rack, ensure that the total component power ratings do not exceed the circuit capabilities. Overloaded power sources and extension cables present fire and shock hazards. • Elevated ambient temperature-If you install the switch in a closed rack assembly, the operating temperature of the rack environment may be greater than the room ambient temperature. Use care not to exceed the 45°C (113°F) maximum ambient temperature of the switch. • Reduced airflow-Do not compromise the amount of airflow needed for safe operation of the equipment. Install the equipment in the rack so that the equipment constantly has the correct amount of airflow surrounding it. • Reliable earthing-Maintain reliable earthing of rack-mounted equipment. Pay particular attention to the supply connections other than the direct connections to the branch circuit, for example; use of power strips. • Do not mount the equipment with the fan panel facing in the downward position. Chassis installation and removal 1. Align the chassis with the rails and slide the chassis into the rack. 2. Tighten the screws on each side of the chassis's front panel, items 1 and 2. To remove the chassis from the rack, loosen the screws and slide the chassis out of the rack. 18 S5200F-ON Series switch Installation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

3.
Tighten the two thumb screws and rack screws.
To remove the chassis from the rack or cabinet, press in the two side-release bars on the chassis at the same time and slide the chassis
forward.
Two U four-post rack assembly
Due to the chassis weight, the S5296F-ON switch does not support a two-post rack installation; you must install the S5296F-ON in a
four-post rack.
NOTE:
To install the S5212F-ON, see
One-half U front-rack installation
. To install the S5232F-ON, S5248F-ON, or
S5224F-ON switch, see
One U ReadyRails installation
.
To install in a four-post rack, follow the instructions in your rack frame kit. In a four-post rack, the maximum distance between the front
and back vertical posts is 36 inches (91.44 cm); the minimum distance is 24 inches (60.96).
CAUTION:
Use two people, an equipment lift, or pallet jack when lifting or moving the chassis. Install the chassis into
the rack before inserting the chassis components. Lift the chassis only from the bottom. Lifting by the chassis shelves
or power supply openings might damage the chassis.
Four-post rack mount
Rack mounting safety considerations
NOTE:
To prevent bodily injury when mounting or servicing this unit in a rack, take special precautions to ensure that
the chassis remains stable. The following guidelines are provided to ensure your safety:
If your chassis is the only unit in the rack, mount it at the bottom of the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest
component at the bottom of the rack.
If the rack comes with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.
If the chassis ships with blanks, remove the blanks from each slot before lifting the chassis.
NOTE:
These instructions are a condensed reference. Read the safety instructions in your
Safety, Environmental, and
Regulatory
information booklet before you begin.
NOTE:
The illustrations in this document are not intended to represent a specific switch.
Rack loading—Overloading or uneven loading of racks may result in shelf or rack failure, possibly damaging the equipment and causing
personal injury. Stabilize racks in a permanent location before loading begins. Mount the components starting at the bottom of the
rack, then work to the top. Do not exceed your rack’s load rating.
Power considerations—Connect only to the power source specified on the unit. When you install multiple electrical components in a
rack, ensure that the total component power ratings do not exceed the circuit capabilities. Overloaded power sources and extension
cables present fire and shock hazards.
Elevated ambient temperature—If you install the switch in a closed rack assembly, the operating temperature of the rack environment
may be greater than the room ambient temperature. Use care not to exceed the 45°C (113°F) maximum ambient temperature of the
switch.
Reduced airflow—Do not compromise the amount of airflow needed for safe operation of the equipment. Install the equipment in the
rack so that the equipment constantly has the correct amount of airflow surrounding it.
Reliable earthing—Maintain reliable earthing of rack-mounted equipment. Pay particular attention to the supply connections other
than the direct connections to the branch circuit, for example; use of power strips.
Do not mount the equipment with the fan panel facing in the downward position.
Chassis installation and removal
1.
Align the chassis with the rails and slide the chassis into the rack.
2.
Tighten the screws on each side of the chassis’s front panel, items 1 and 2.
To remove the chassis from the rack, loosen the screws and slide the chassis out of the rack.
18
S5200F-ON Series switch Installation