E-Z-GO RXV - Electric Owner Manual - Page 45

Using A Hydrometer

Page 45 highlights

B OPERATION AND SERVICE INFORMATION Read all of manual to become familiar with this vehicle. Pay attention to all NOTICES, CAUTIONS, WARNINGS and DANGERS. To prevent battery explosion that could result in severe personal injury or death, never insert a metal thermometer into a battery. Use a hydrometer with a built in thermometer that is designed for testing batteries. Specific gravity is the measurement of a liquid that is compared to a baseline. The baseline is water which is assigned a base number of 1.000. The concentration of sulfuric acid to water in a new golf car battery is 1.280 which means that the electrolyte weighs 1.280 times the weight of the same volume of water. A fully charged battery will test at 1.275 - 1.280 while a discharged battery will read in the 1.140 range. NOTICE Do not perform a hydrometer test on a battery that has just been watered. The battery must go through at least one charge and discharge cycle in order to permit the water to adequately mix with the electrolyte. B temperature is 90° F (32° C), add four points (.004) to the 1.250 which gives a corrected reading of 1.254. Similarly if the temperature was 70° F (21° C), subtract four points (.004) from the 1.250 to give a corrected reading of 1.246. 5. Test each cell and note the readings (corrected to 80° F or 27° C). A variation of fifty points between any two cell readings (example 1.250 - 1.200) indicates a problem with the low reading cell(s). As a battery ages the specific gravity of the electrolyte will decrease at full charge. This is not a reason to replace the battery providing all cells are within fifty points of each other. Since the hydrometer test is in response to a vehicle exhibiting a performance problem , the vehicle should be recharged and the test repeated. If the results indicate a weak cell, the battery or batteries should be removed and replaced with a good battery of the same brand, type and approximate age. The temperature of the electrolyte is important since the hydrometer reading must be corrected to 80° F (27° C). High quality hydrometers are equipped with an internal thermometer that will measure the temperature of the electrolyte and will include a conversion scale to correct the float reading. It is important to recognize that the electrolyte temperature is significantly different from the ambient temperature if the vehicle has been operated. USING A HYDROMETER 1. Draw electrolyte into the hydrometer several times to permit the thermometer to adjust to the electrolyte temperature and note the reading. Examine the color of the electrolyte. A brown or gray coloration indicates a problem with the battery and is a sign that the battery is nearing the end of its life. 2. Draw the minimum quantity of electrolyte into the hydrometer to permit the float to float freely without contacting the top or bottom of the cylinder. 3. Hold the hydrometer in a vertical position at eye level and note the reading where the electrolyte meets the scale on the float. 4. Add or subtract four points (.004) to the reading for every 10° F (6° C) the electrolyte temperature is above or below 80° F (27° C). Adjust the reading to conform with the electrolyte temperature, e.g., if the reading indicates a specific gravity of 1.250 and the electrolyte Fig. 32 Hydrometer Temperature Correction Owner's Guide Page 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

OPERATION AND SERVICE INFORMATION
Page 25
Owner’s Guide
Read all of manual to become familiar with this vehicle. Pay attention to all NOTICES, CAUTIONS, WARNINGS and DANGERS.
B
B
To prevent battery explosion that could result
in severe personal injury or death, never insert
a metal thermometer into a battery. Use a
hydrometer with a built in thermometer that is
designed for testing batteries.
Specific gravity is the measurement of a liquid that is
compared to a baseline. The baseline is water which is
assigned a base number of 1.000. The concentration of
sulfuric acid to water in a new golf car battery is 1.280
which means that the electrolyte weighs 1.280 times the
weight of the same volume of water. A fully charged bat-
tery will test at 1.275 - 1.280 while a discharged battery
will read in the 1.140 range.
Do not perform a hydrometer test on a battery that has just
been watered. The battery must go through at least one
charge and discharge cycle in order to permit the water to ade-
quately mix with the electrolyte.
The temperature of the
electrolyte
is important since
the hydrometer reading must be corrected to 80° F (27°
C). High quality hydrometers are equipped with an inter-
nal thermometer that will measure the temperature of
the electrolyte and will include a conversion scale to
correct the float reading. It is important to recognize that
the electrolyte temperature is significantly different from
the ambient temperature if the vehicle has been operat-
ed.
USING A HYDROMETER
1.
Draw electrolyte into the hydrometer several times to
permit the thermometer to adjust to the electrolyte
temperature and note the reading. Examine the color
of the electrolyte. A brown or gray coloration indicates
a problem with the battery and is a sign that the bat-
tery is nearing the end of its life.
2.
Draw the minimum quantity of electrolyte into the hy-
drometer to permit the float to float freely without con-
tacting the top or bottom of the cylinder.
3.
Hold the hydrometer in a vertical position at eye level
and note the reading where the electrolyte meets the
scale on the float.
4.
Add or subtract four points (.004) to the reading for ev-
ery 10° F (6° C) the electrolyte temperature is above
or below 80° F (27° C). Adjust the reading to conform
with the electrolyte temperature, e.g., if the reading in-
dicates a specific gravity of 1.250 and the electrolyte
temperature is 90° F (32° C),
add
four points (.004) to
the 1.250 which gives a corrected reading of 1.254.
Similarly if the temperature was 70° F (21° C),
sub-
tract
four points (.004) from the 1.250 to give a cor-
rected reading of 1.246.
5.
Test each cell and note the readings (corrected to 80°
F or 27° C). A variation of fifty points between any two
cell readings (example 1.250 - 1.200) indicates a
problem with the low reading cell(s).
As a battery ages the specific gravity of the electrolyte
will decrease at full charge. This is not a reason to re-
place the battery providing all cells are within fifty points
of each other.
Since the hydrometer test is in response to a vehicle ex-
hibiting a performance problem , the vehicle should be
recharged and the test repeated. If the results indicate a
weak cell, the battery or batteries should be removed
and replaced with a good battery of the same brand,
type and approximate age.
Fig. 32
Hydrometer Temperature Correction
NOTICE