Replacing Ribbon Cassettes, Ink Ribbon Replacement Time, Replacement Procedure
View all Epson SureLab D3000 - Single Roll manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
Replacing Ribbon Cassettes Replacing Ribbon Cassettes When the back printing unit is installed, replace the Ribbon cassette if back printing is too light. See the following section for the replacement Ribbon cassette. U "Consumables and Optional Products" on page 138 Note: Do not perform back printing if the Ribbon cassette is not inserted. Otherwise, paper could be jammed or the back printing unit could be damaged. Ink Ribbon Replacement Time When using an ink ribbon, back printing is light. A different ink ribbon is used to print the first and second lines during back printing. If the first line is too light, replace the Ribbon cassette that is further inside the back printing unit. If the second line is too light, replace the ribbon cassette at the front. The ink ribbon can still be used The ink ribbon needs to be replaced Tip: There are no light indications or error messages when it is time to replace the ribbon. Replacement Procedure ! Caution: When replacing the Ribbon cassette, do not touch the part with a warning label attached. Because it reaches high temperatures, burns could occur. A Check that the p light on the Operation panel is lit. 69