Epson TM-T88V TM-T88V Technical Reference Guide - Page 58

For Parallel Interface, For Built-in USB Interface

Page 58 highlights

For Parallel Interface When using the built-in USB interface, it is not necessary to change the DIP switch setting but their function changes. For the details, see "For Built-in USB Interface" on page 59. DIP Switch Bank 1 SW 1-1 1-2 1-3 1-4 1-5 ∼ 1-8 Function Auto line feed Receive buffer capacity Selects paper sensors to output paper-end signals (default value of a command) Error signal output Undefined ON OFF Always enabled 45 bytes Disabled Disabled Always disabled 4 KB Roll paper end sensor enabled, roll paper near-end sensor enabled Enabled - Default setting OFF OFF OFF OFF OFF DIP Switch Bank 2 SW 2-1 2-2 2-3 ∼ 2-4 2-5 2-6 ∼ 2-7 2-8 Function ON OFF Handshaking (BUSY condition) • Offline Receive buffer full • Receive buffer full Reserved (Do not change setting) Fixed to OFF Selects print density See "Selecting the Print Density (DIP Switches 2-3/2-4)" on page 62. Releases the BUSY Releases the BUSY Sets the release condition of the state when the state when the receive buffer BUSY state. (This remaining capacity remaining capacity function is effective when DIP of the receive buffer of the receive buffer Switch 1-2 is set to off.) reaches 138 bytes. reaches 256 bytes. Reserved (Do not change settings) Fixed to OFF IF pin 31 reset signal (Do not change setting) Fixed to ON Default setting OFF OFF OFF OFF OFF ON For DIP Switch 2-1 (BUSY condition), see also "Selecting the BUSY Status" on page 62. 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

58
For Parallel Interface
When using the built-in USB interface, it is not necessary to change the DIP switch setting but
their function changes. For the details, see
"For Built-in USB Interface" on page 59
.
DIP Switch Bank 1
DIP Switch Bank 2
SW
Function
ON
OFF
Default
setting
1-1
Auto line feed
Always enabled
Always disabled
OFF
1-2
Receive buffer capacity
45 bytes
4 KB
OFF
1-3
Selects paper sensors to output
paper-end signals (default
value of a command)
Disabled
Roll paper end sensor
enabled, roll paper
near-end
sensor
enabled
OFF
1-4
Error signal output
Disabled
Enabled
OFF
1-5
1-8
Undefined
OFF
SW
Function
ON
OFF
Default
setting
2-1
Handshaking (BUSY condition)
Receive buffer full
Offline
Receive buffer full
OFF
2-2
Reserved (Do not change
setting)
Fixed to OFF
OFF
2-3
2-4
Selects print density
See
"Selecting the Print Density (DIP Switches
2-3/2-4)" on page 62
.
OFF
2-5
Sets the release condition of the
receive buffer BUSY state. (This
function is effective when DIP
Switch 1-2 is set to off.)
Releases the BUSY
state
when
the
remaining capacity
of the receive buffer
reaches 138 bytes.
Releases the BUSY
state
when
the
remaining capacity
of the receive buffer
reaches 256 bytes.
OFF
2-6
2-7
Reserved (Do not change
settings)
Fixed to OFF
OFF
2-8
IF pin 31 reset signal (Do not
change setting)
Fixed to ON
ON
For DIP Switch 2-1 (BUSY condition), see also
"Selecting the BUSY Status" on page 62
.