Hayward AquaRite 100 AquaRite 100 Owners Manual - Page 18
Blinking, Possible Actions, Possible, Cause
View all Hayward AquaRite 100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Led Blinking Min LED LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 LED 9 LED 8 MAX LED Inadequate Water Flow Standing By Possible Cause Possible Actions Low Salt 1. Check the salt level in the pool and verify the salt level is greater than 1500 ppm but also less than 4500 ppm. 2. Inspect the Cell. If dirty, follow the Cell cleaning procedure. 3. Inspect the Cell Vessel and verify the Cell plates are fully covered by moving water. 4. Remove power to the AQR100 for two minutes and then re-apply. High Salt 1. Check that the salt level in the pool is no greater than 4500 ppm and/or the temperature does not exceed 104ºF. 2. Remove power to the AQR100 for two minutes and then re-apply. Low Input Power 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Verify that the AQR100 is input power wiring is correct (page 7). Make sure that there is adequate input voltage (a brown out condition could cause this error). Temperature 1. Remove power to the AQR100 for two minutes and then re-apply. Sensor Error 2. Inspect the Cell. If dirty, follow the Cell cleaning procedure. Internal Error 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Check that the salt level in the pool is no greater than 4500 ppm and/or the temperature does not exceed 104ºF. 3. Inspect the Cell Vessel and verify the cell plates are fully covered by moving water. 4. Contact Hayward Technical Service. No Current to Cell 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Inspect the cable that connects the cell to the system. Make sure the cable is secure and undamaged. 3. Turn on Super Chlorinate briefly and go back to original setting. 4. Inspect the Cell Vessel and verify the cell plates are fully covered by moving water. Cell Error 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Inspect the cable that connects the cell to the system. Make sure the cable is secure and undamaged. 3. Contact Hayward Technical Service. Low Flow or No Flow Condition 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Check for obstructions or a flow related cause in your pool's plumb- ing system. Water Temperature Error 1. Remove power to the AQR100 for two minutes and then re-apply. 2. Check that the pool temperature is more than 50ºF and less than 104ºF. 17 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS