Hayward AquaRite 100 AquaRite 100 Owners Manual - Page 9

Bonding

Page 9 highlights

Bonding Pool bonding or "equipotential bonding" ensures that all pool components around the pool are at the same electrical potential. If bonding is required at your location (see Local and NEC codes), bonding lugs are is provided at the bottom of the AQR100 enclosure. Run an 8 AWG solid copper wire (6 AWG Canada) from the bonding lug to your pool's existing bonding loop. To Pool Bonding loop IMPORTANT: Before going any further, the pool water must be balanced and salt must be added to your pool. If this has not already been done, refer to the "Pool Chemistry" section on page 9 of this manual for information on how to prepare your pool water for AQR100 operation. 8 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
Bonding
Pool bonding or “equipotential bonding” ensures that all pool components around the pool are at the
same electrical potential. If bonding is required at your location (see Local and NEC codes), bonding
lugs are is provided at the bottom of the AQR100 enclosure.
Run an 8 AWG solid copper wire (6 AWG
Canada) from the bonding lug to your pool’s existing bonding loop.
IMPORTANT:
Before going any further, the pool water must be balanced and salt must be added to
your pool.
If this has not already been done, refer to the “Pool Chemistry” section on page 9 of this
manual for information on how to prepare your pool water for AQR100 operation.
To Pool Bonding loop