Plumbing
View all Hayward AquaRite 100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Plumbing The Cell Vessel is designed to install in 2" (51mm) PVC pool plumbing. For pools using 1½" (38 mm) polypipe, you must use a 2" adapter. The Cell Vessel must be installed on approximately 10" run of straight pipe at the end of the return piping just before the water returns to the pool. All pool equipment should be upstream from the Cell Vessel as shown in the diagram below. It must be located within 15 feet of where the Control Box is mounted. Also, position the Vessel in a manner where the Cell can be easily inserted and removed. With power removed to the pump and water drained from the pool plumbing, cut the plumbing in the desired location and glue the unions to the pipe. Install the included rubber gaskets on the Cell Vessel then install the Cell Vessel into the plumbing by handtightening the unions. Install gaskets on Cell Vessel before installation When choosing an installation location, allow enough cord to easily insert/remove the cell FROM POOL TO POOL Remove the foam protector from the Cell. Verify that the O-Ring is attached before inserting the Cell into the Cell Vessel. Fully cover Cell pins with supplied grease as shown. Grease O-Ring 5 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS