HP 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01, July 2009) - Page 488
L2SS-1005, L2SS-1006, L2SS-1007
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 488 highlights
60 L2SS-1005 DRAFT: BROCADE CONFIDENTIAL Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1005 Message , [L2SS-1005], ,, ERROR, , Mac-address-table hash failed even after two attempts for slot chip . Probable Cause Indicates a mac-address-table hash failure happened even after two hash changes on the chip. Recommended Restart the l2sysd daemon. Action Severity ERROR L2SS-1006 Message , [L2SS-1006], ,, INFO, , Mac-address-table table on slot chip is 95 percent full. Probable Cause Indicates that the mac-address-table on the chip is 95% full. Recommended Clear some of the entries, or wait till old entries age out. Action Severity INFO L2SS-1007 Message , [L2SS-1007], ,, INFO, , MMac-address-table on slot chip is less than 90 percent full. Probable Cause Indicates that the mac-address-table is less than 90% full. Recommended No action is required. L2SYS will start learning the entries. Action Severity INFO 418 Fabric OS Message Reference 53-1001338-01