HP 8/40 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01, July 2009) - Page 689
TRCE-1007, Message, Probable Cause, Recommended, Action, supportFtp, supportSave, Severity, haShow
View all HP 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 689 highlights
10 TRCE-1007 TRCE-1007 Message , [TRCE-1007], ,, ERROR, , Notification of this CP has failed. Parameters temporarily out of synch with other CP. Probable Cause Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is only applicable to the Brocade 24000, and 48000. Recommended Action This message is often transitory. Wait for a few minutes and retry the command. If the message persists, run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1008 Message , [TRCE-1008], , FFDC, CRITICAL, , Unable to load trace parameters. Probable Cause Indicates that the active CP is unable to read stored trace parameters. Recommended Action Restart the CP (dual-CP system) or restart the switch. If the message persists, run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL TRCE-1009 Message , [TRCE-1009], ,, ERROR, , Unable to alert active CP that a dump has occurred. Probable Cause Indicates that the standby CP is unable to communicate trace information to active CP. This message is only applicable to the Brocade 24000 and 48000. Recommended Action Run the haShow command to verify that the current CP is standby and the active CP is active. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR TRCE-1010 Message , [TRCE-1010], ,, ERROR, , Traced fails to start Fabric OS Message Reference 619 53-1001338-01