HP A7533A HP StorageWorks Fabric OS 6.x administrator guide (5697-0015, May 20 - Page 236
Dual backbone configuration, Maximum LSAN count
UPC - 829160830858
View all HP A7533A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 236 highlights
--cancel --display --fabricview --verify --quickmode Clears the information from the cache and put it back to the saved value. Displays the information that is saved in the cache. Displays the static and default and dynamic binding of the backbone to show which edge fabrics can access each other. Verifies if the information in the cache is valid and will not disrupt existing import/export devices. Runs a quick mode to derive the LSAN Zone matrix from the current import/export database. NOTE: The command fcrlsanmatrix --add 0 0 will erase the entire LSAN Zone Matrix settings in the cache. To set up LSAN zone binding: 1. Log in to the switch as admin. 2. Enter the followng command to add a pair: FCR:Admin > fcrlsanmatrix --add 3. Enter the following command to apply the changes persistently: FCR:Admin > fcrlsanmatrix --apply To view the LSAN zones static and dynamic bindings: 1. Log on to the switch as admin. 2. Enter the command as follows: fcrlsanmatrix --fabricview The following is an example: FCR:Admin > fcrlsanmatrix --fabricview LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 4 5 4 7 10 19 Default LSAN Matrix: 1 2 8 See the Fabric OS Command Reference Manual for additional information on the fcrlsanmatrix command. Dual backbone configuration When dual backbones share edge fabrics, one of the backbones is selected to be the owner of the edge fabric which sends device state updates to the other backbone through the shared edge fabric. When the 'LSAN Zone binding' feature is enabled, the LSAN Zone Matrix settings for the shared edge fabrics must be the same on both backbones. Both backbone fabrics must have the same LSAN Zone Matrix settings. If the settings are different, the outcome will be inconsistent. Both backbone fabrics will end up having the setup of the owner fabric which can change on reboot or on a port disable or enable. Maximum LSAN count The fcrlsancount command lets you configure the maximum number of LSANs, or LSAN count, that can be configured on the edge fabric, which is up to 5000 without disabling the switch. By default, the maximum LSAN count is set to 3000. This command lets you create more LSANs on your edge fabric where needed. The maximum number of devices supported is still 10000. 236 Using the FC-FC routing service