Devices directly connected to router
UPC - 829160830858
View all HP A7533A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 259 highlights
Figure 18 Dual backbone fabric configuration Devices directly connected to router In the Multi-protocol Router, end devices are allowed to be directly connected, but these devices cannot be imported to other edge fabrics (using LSAN zones). During the upgrade process, these devices will face disruption unless there is redundancy support provided from the device end. 400 MP Router allows the end devices to be imported to edge fabrics. To configure the new router: 1. Log in to the new router as admin. 2. Enable FCR functionality on the 400 MP Router. a. On Fabric OS v5.2.x and earlier use the fcrenable command. b. On Fabric OS v5.3.0 and later use the fosconfig -enable fcr command. 3. Set respective fabric IDs while configuring each of the EX_Ports using the portcfgexport -f command. 4. Verify that the operating mode is native while configuring the EX_Port using the portcfgexport -m command. 5. Set the BB Fabric ID using the fcrconfigure command. 6. Set other fabric parameters using the configure command, if they are not default. 7. You may choose to manually configure the xlate Domain IDs on the new router, to match with old router using the fcrxlateconfig command. 8. You may choose to manually configure the Area and AL_PA portions of the proxy device PID, using the fcrproxyconfig command. Fabric OS 6.x administrator guide 259