HP A7533A HP StorageWorks Fabric OS 6.x administrator guide (5697-0015, May 20 - Page 254
LSAN zoning with M-EOS
UPC - 829160830858
View all HP A7533A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 254 highlights
Figure 14 Adding a zone set name in SAN Pilot Regardless of the method used, you should now verify that the new zone set containing your LSAN has been added. Alternately, use the following procedure: 1. Create the LSAN, using the LSAN_xxxx naming schema. 2. Append the newly-created zone set to a currently active zone set. 3. Activate the updated zone set. LSAN zoning with M-EOS An LSAN is defined by a zone in an edge fabric. When zoning an LSAN containing multiple manufacturers' fabrics (such as a Brocade-Cisco SAN), you must use port WWN. Because port IDs are not necessarily unique across fabrics, you cannot use the domain,port method of identification. If the LSAN is configured and the proxy devices are created, the proxy device will show in the name server of the edge fabric and the xlate domain will show in the fabric of the edge fabric. For more details about LSAN zoning, see "Configuring LSANs and zoning" on page 231. If the LSAN devices appear in only one of the fabrics in a multiple-fabric SAN, use the following procedure to correct the problem. To correct errors if LSAN devices appear in only one of the fabrics: 1. Log in to each fabric and verify that all of the devices are physically logged in. 2. Verify that the devices are properly configured in the LSAN zone in both edge fabrics. 3. Issue the fabricShow command on the Brocade fabric. 4. Use M-EOS EFCM or SAN Pilot to verify the M-EOS fabric, including the front and translation domains. 254 Using the FC-FC routing service