HP Bc1500 User Guide: HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 104

Set Display Events [on | Off]

Page 104 highlights

Performing Common Administrative Tasks To identify a degraded component using the CLI: 1. Type: SET DISPLAY EVENTS [ON | OFF] Choosing the on option for this command ensures that all users are able to see failures as they occur while they are logged into the Integrated Administrator. 2. Type the appropriate commands: SHOW ENCLOSURE FAN [ | ALL] This command displays the status, redundancy, partner, speed, and part number for one or all fans in the enclosure. SHOW ENCLOSURE INFO This command displays the enclosure name, type, part number, serial number, and asset tag number; the Integrated Administrator software and hardware version; the MAC address of the Integrated Administrator, and the interconnect tray type, part number, and serial number. SHOW ENCLOSURE POWERSUPPLY [ | ALL] This command displays the status, AC input status, capacity, input voltage range #1 (Volts), input voltage range #2 (Volts), input frequency range (Hz), part number, serial number, and hardware revision for one or both power supplies in the enclosure. SHOW ENCLOSURE STATUS This command displays the status of enclosure health, Integrated Administrator health, and the Unit Identification LED under the heading "enclosure status," and displays the status and capacity of the power supplies of the enclosure under the heading "power status." SHOW ENCLOSURE TEMP This command displays the location, status (OK, warm, degraded, or failed), and temperature (degrees Fahrenheit or Celsius) for all the temperature sensors of the enclosure. 7-12 HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

7-12
HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
Performing Common Administrative Tasks
To identify a degraded component using the CLI:
1. Type:
SET DISPLAY EVENTS [ON | OFF]
Choosing the on option for this command ensures that all users are able to see failures as they
occur while they are logged into the Integrated Administrator.
2. Type the appropriate commands:
SHOW ENCLOSURE FAN [<fan number> | ALL]
This command displays the status, redundancy, partner, speed, and part number for one or all
fans in the enclosure.
SHOW ENCLOSURE INFO
This command displays the enclosure name, type, part number, serial number, and asset tag
number; the Integrated Administrator software and hardware version; the MAC address of the
Integrated Administrator, and the interconnect tray type, part number, and serial number.
SHOW ENCLOSURE POWERSUPPLY [<power supply number> | ALL]
This command displays the status, AC input status, capacity, input voltage range #1 (Volts),
input voltage range #2 (Volts), input frequency range (Hz), part number, serial number, and
hardware revision for one or both power supplies in the enclosure.
SHOW ENCLOSURE STATUS
This command displays the status of enclosure health, Integrated Administrator health, and the
Unit Identification LED under the heading “enclosure status,” and displays the status and
capacity of the power supplies of the enclosure under the heading “power status.”
SHOW ENCLOSURE TEMP
This command displays the location, status (OK, warm, degraded, or failed), and temperature
(degrees Fahrenheit or Celsius) for all the temperature sensors of the enclosure.