HP Bc1500 User Guide: HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 40

Console Log, Administration Tab

Page 40 highlights

Web Browser Interface The Virtual Buttons screen enables group administrators and enclosure administrators to reboot, power off, or identify the blade PC with the following items: ■ The Toggle On/Off button remotely changes the state of the blade PC Unit Identification LED. ■ You can select the appropriate function in the Blade PC Power area using the following radio buttons: ❏ Reboot reboots the blade PC. ❏ Power Off attempts a graceful shutdown of the blade PC for 5 minutes, after which time this command powers down the blade PC immediately. ❏ Power Off Immediately powers off the blade PC forcefully. Ä CAUTION: Without the blade PC health driver or an ACPI-compliant operating system, the Integrated Administrator cannot gracefully shut down a blade PC. This condition can result in the permanent loss of critical data. ✎ Click Apply for these settings to take effect. ✎ Whenever possible, HP recommends that you use the operating system shutdown procedures before powering down a blade PC or enclosure. Once the enclosure is powered off, powering on can only occur with local access to the system. Console Log ✎ Only group members, group administrators, and enclosure administrators can view a console log of a blade PC. The Console Log screen displays the console log for the specified bay. The console log of the bay is not stored between reboots of the Integrated Administrator, so the information will only include what has taken place since the last power on of the Integrated Administrator. The data captured in the console log is all output from the serial console of the blade PC that occurred while no one was connected to the console. For security reasons, console output during a user connection session is not logged. The Refresh button refreshes the console log for the current blade PC. Administration Tab For an explanation of user rights associated with the Integrated Administrator, see Chapter 6, section " Enabling Remote Console Sessions to Blade PCs." Under the Administration tab, you can access the following screens: ■ User List ■ Group List ■ Add User ■ Add Group 4-18 HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

4-18
HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
Web Browser Interface
The Virtual Buttons screen enables group administrators and enclosure administrators to reboot,
power off, or identify the blade PC with the following items:
The
Toggle On/Off
button remotely changes the state of the blade PC Unit Identification
LED.
You can select the appropriate function in the Blade PC Power area using the following radio
buttons:
Reboot
reboots the blade PC.
Power Off
attempts a graceful shutdown of the blade PC for 5 minutes, after which time
this command powers down the blade PC immediately.
Power Off Immediately
powers off the blade PC forcefully.
Ä
CAUTION:
Without the blade PC health driver or an ACPI-compliant operating system, the Integrated
Administrator cannot gracefully shut down a blade PC. This condition can result in the permanent loss of
critical data.
Click
Apply
for these settings to take effect.
Whenever possible, HP recommends that you use the operating system shutdown procedures
before powering down a blade PC or enclosure. Once the enclosure is powered off, powering on
can only occur with local access to the system.
Console Log
Only group members, group administrators, and enclosure administrators can view a console log
of a blade PC.
The Console Log screen displays the console log for the specified bay. The console log of the bay
is not stored between reboots of the Integrated Administrator, so the information will only
include what has taken place since the last power on of the Integrated Administrator.
The data captured in the console log is all output from the serial console of the blade PC that
occurred while no one was connected to the console. For security reasons, console output during
a user connection session is not logged.
The
Refresh
button refreshes the console log for the current blade PC.
Administration Tab
For an explanation of user rights associated with the Integrated Administrator, see Chapter 6,
section “ Enabling Remote Console Sessions to Blade PCs.”
Under the Administration tab, you can access the following screens:
User List
Group List
Add User
Add Group