HP Bc1500 User Guide: HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 27

Enclosure Information Field Descriptions

Page 27 highlights

Web Browser Interface The following table describes the information displayed in the areas that comprise the Enclosure Information screen. Enclosure Information Field Descriptions Field Possible Values Description Status Area Enclosure Name Maximum 32 characters including all alphanumeric, dash, and underscore characters. Name of enclosure. Only enclosure administrators have write access to this field. For the default enclosure name, see Appendix E, "Factory Default Settings." Rack Name Maximum 32 characters including all alphanumeric, dash, and underscore characters. Name of rack. Only enclosure administrators have write access to this field. For the default rack name, see Appendix E, "Factory Default Settings." Enclosure Status OK, Degraded, or Failed. Status of the enclosure. Fan Status Redundant or non-redundant. Redundant: all fans are functional. Non-redundant: at least one fan is not functional. Fan #1 - Fan #4 OK, Standby, Degraded, Failed, or Testing. Percentage of full fan speed. Status of fans 1 through 4. Fan Spare Number The spare number for the fans installed in the enclosure. Temperature OK, Warm, Caution, or Critical. Enclosure component temperature sensor. Power Area Power Subsystem Status Redundant or Non-redundant. Redundant: both power supplies are functional. Non-redundant: one power supply is not functional. Total Capacity Watts. Total capacity of the power supplies. Power Supply #1 and #2 Status OK, Degraded, or Failed. Status of power supply #1 and power supply #2. AC Input #1 and #2 Status OK, Degraded, or Failed. Status of AC input to power supply #1 and AC input to power supply #2. Power Supply Spare Number The spare number for the power supplies installed in the enclosure. HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide 4-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
4-5
Web Browser Interface
The following table describes the information displayed in the areas that comprise the Enclosure
Information screen.
Enclosure Information Field Descriptions
Field
Possible Values
Description
Status Area
Enclosure
Name
Maximum 32 characters
including all alphanumeric,
dash, and underscore
characters.
Name of enclosure.
Only enclosure administrators have write
access to this field.
For the default enclosure name, see
Appendix E, “Factory Default Settings.”
Rack Name
Maximum 32 characters
including all alphanumeric,
dash, and underscore
characters.
Name of rack.
Only enclosure administrators have write
access to this field.
For the default rack name, see Appendix
E, “Factory Default Settings.”
Enclosure
Status
OK, Degraded, or Failed.
Status of the enclosure.
Fan Status
Redundant or non-redundant.
Redundant: all fans are functional.
Non-redundant: at least one fan is not
functional.
Fan #1 —
Fan #4
OK, Standby, Degraded,
Failed, or Testing.
Percentage of full fan speed.
Status of fans 1 through 4.
Fan Spare
Number
The spare number for the fans installed in
the enclosure.
Temperature
OK, Warm, Caution, or
Critical.
Enclosure component temperature sensor.
Power Area
Power
Subsystem
Status
Redundant or Non-redundant.
Redundant: both power supplies are
functional. Non-redundant: one power
supply is not functional.
Total Capacity
Watts.
Total capacity of the power supplies.
Power Supply
#1 and #2
Status
OK, Degraded, or Failed.
Status of power supply #1 and power
supply #2.
AC Input #1
and #2 Status
OK, Degraded, or Failed.
Status of AC input to power supply #1 and
AC input to power supply #2.
Power Supply
Spare Number
The spare number for the power supplies
installed in the enclosure.