HP Bc1500 User Guide: HP BladeSystem PC Blade Enclosure Integrated Administrat - Page 64

Command, UnnamedRack

Page 64 highlights

Command Line Interface Enclosure Management Commands (continued) Command Description Restrictions SHOW ENCLOSURE POWER SUPPLY [ | ALL] Displays the power supply status, AC input status, capacity, input voltage range #1 (measured in Volts), input voltage range #2 (if necessary, measured in Volts), input frequency range (measured in Hertz), part number, serial number, and hardware revision for the specified power supply if one is specified or for all power supplies if ALL is given. None SHOW ENCLOSURE STATUS Under an enclosure status heading, this command displays the health, Integrated Administrator health, and unit identification LED of the enclosure. Under a power status heading, this command displays the power status and capacity. None SHOW ENCLOSURE TEMP Displays the locale, status (OK, warm, degraded, or failed), temperature in degrees Fahrenheit, and temperature sensors. None SHOW RACK NAME Shows the name for the rack where the enclosure resides The default rack name is UnnamedRack. None SHOW SYSLOG ENCLOSURE Displays the syslog of the enclosure with 22 lines per screen. Typing q quits the command, any other key shows the next screen if more information exists to display. Typing c continuously displays the System Log without page breaks. Only enclosure administrators may execute this command. SHOW TRAY INFO Displays the manufacturer, product name, part number, serial number, and spare number of the interconnect tray. None 5-14 HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

5-14
HP PC Blade Enclosure Integrated Administrator for CCI v1.4 User Guide
Command Line Interface
Enclosure Management Commands (continued)
Command
Description
Restrictions
SHOW
ENCLOSURE
POWER
SUPPLY
[<power supply
number> | ALL]
Displays the power supply status, AC input
status, capacity, input voltage range #1
(measured in Volts), input voltage range
#2 (if necessary, measured in Volts), input
frequency range (measured in Hertz), part
number, serial number, and hardware
revision for the specified power supply if
one is specified or for all power supplies if
ALL is given.
None
SHOW
ENCLOSURE
STATUS
Under an enclosure status heading, this
command displays the health, Integrated
Administrator health, and unit
identification LED of the enclosure.
Under a power status heading, this
command displays the power status and
capacity.
None
SHOW
ENCLOSURE
TEMP
Displays the locale, status (OK, warm,
degraded, or failed), temperature in
degrees Fahrenheit, and temperature
sensors.
None
SHOW RACK
NAME
<rack name>
Shows the name for the rack where the
enclosure resides
The default rack name is
UnnamedRack
.
None
SHOW
SYSLOG
ENCLOSURE
Displays the syslog of the enclosure with
22 lines per screen.
Typing
q
quits the command, any other
key shows the next screen if more
information exists to display.
Typing
c
continuously displays the System
Log without page breaks.
Only enclosure administrators
may execute this command.
SHOW TRAY
INFO
Displays the manufacturer, product name,
part number, serial number, and spare
number of the interconnect tray.
None