HP Cisco Catalyst Blade Switch 3020 Release Notes for Cisco Catalyst Blade Swi - Page 20

Updates to the System Message Guide, New System Messages

Page 20 highlights

Documentation Updates Updates to the System Message Guide • "New System Messages" section on page 20 • "Deleted System Messages" section on page 22 New System Messages Error Message ACLMGR-2-NOVMR: Cannot generate hardware representation of access list [chars] Explanation There are insufficient resources available to create a hardware representation of the ACL. A lack of available logical operation units or specialized hardware resources can cause this problem. Logical operation units are needed for a TCP flag match or a test other than eq (ne, gt, lt, or range) on TCP, UDP, or SCTP port numbers. Recommended Action Modify the ACL configuration to use fewer resources, or rename the ACL with a name or number that alphanumerically precedes the other ACL names or numbers. Error Message %DOT1X-5-FAIL: Authentication failed for client ([chars]) on Interface [chars] Explanation Authentication was unsuccessful. The first [chars] is the hostname, and the second [chars] is the interface. Recommended Action No action is required. Error Message %DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on Interface [chars] Explanation Authentication was successful. The first [chars] is the host name, and the second [chars] is the interface. Recommended Action No action is required. Error Message %DOT1X_SWITCH-4-PROC_START_ERR: Unable to start dot1x switch process. Explanation The software could not start the 802.1x authentication process. Recommended Action Use the reload privileged EXEC command to reload the switch. Error Message %EC-5-MINLINKS_MET: Port-channel [chars] is up as its bundled ports ([dec]) meets min-links Recommended Action The administrative configuration of minimum links is equal to or less than the number of EtherChannel ports. The port channel is up. [chars] is the EtherChannel, and [dec] is the EtherChannel group number. Recommended Action No action is required. Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(50)SE and Later 20 OL-18274-02

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

20
Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(50)SE and Later
OL-18274-02
Documentation Updates
Updates to the System Message Guide
“New System Messages” section on page 20
“Deleted System Messages” section on page 22
New System Messages
Error Message
ACLMGR-2-NOVMR: Cannot generate hardware representation of access list
[chars]
Explanation
There are insufficient resources available to create a hardware representation of the
ACL. A lack of available logical operation units or specialized hardware resources can cause this
problem. Logical operation units are needed for a TCP flag match or a test other than
eq
(
ne
,
gt
,
lt
,
or
range
) on TCP, UDP, or SCTP port numbers.
Recommended Action
Modify the ACL configuration to use fewer resources, or rename the ACL with
a name or number that alphanumerically precedes the other ACL names or numbers.
Error Message
%DOT1X-5-FAIL: Authentication failed for client ([chars]) on Interface
[chars]
Explanation
Authentication was unsuccessful. The first [chars] is the hostname, and the second
[chars] is the interface.
Recommended Action
No action is required.
Error Message
%DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on
Interface [chars]
Explanation
Authentication was successful. The first [chars] is the host name, and the second [chars]
is the interface.
Recommended Action
No action is required.
Error Message
%DOT1X_SWITCH-4-PROC_START_ERR: Unable to start dot1x switch process.
Explanation
The software could not start the 802.1x authentication process.
Recommended Action
Use the
reload
privileged EXEC command to reload the switch.
Error Message
%EC-5-MINLINKS_MET: Port-channel [chars] is up as its bundled ports
([dec]) meets min-links
Recommended Action
The administrative configuration of minimum links is equal to or less than the
number of EtherChannel ports. The port channel is up. [chars] is the EtherChannel, and [dec] is the
EtherChannel group number.
Recommended Action
No action is required.