HP Cisco MDS 8/24c Cisco MDS 8Gb Fabric Switch for HP BladeSystem c-Class User - Page 32

Weight and physical dimensions, Environmental requirements, Supported SFPs

Page 32 highlights

Weight and physical dimensions Table 7 lists physical properties. Table 7 Physical dimensions Dimension Measurement Height 29.3 mm (1.15 in) Width Depth Weight 208 mm (8.19 in) 280 mm (11.02 in) 1.27 kg (2.8 lb) Environmental requirements To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for which it was tested. The ranges specified in Table 8 on page 32 list the acceptable environment for both operating and non-operating conditions. Table 8 Environmental requirements Condition Acceptable range during operation Acceptable range during non-operation Ambient temperature 104°F/40°C at sea level, derated 34°F/1°C per 1000 ft above sea level -40°F/-40°C to 58°F/70°C with maximum rate of change of 68°F/20°C /hr Humidity 5% to 90% relative humidity, non-condensing 50% to 80% relative humidity, non-condensing Altitude 0 to 10,000 ft (3 km) above sea level 0 to 40,000 ft (12 km) above sea level Shock 40 G, 2mS duration 140 G, 2mS duration Vibration 0.5 G, 10 to 500 Hz 2.0 G, 5 to 500 Hz Airflow 47 cubic ft per minute None required Supported SFPs Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly and may void your warranty. See "Optional hardware" on page 10 for a list of supported SFPs. For a complete list of supported devices, see the HP StorageWorks Single Point of Connectivity Knowledge (SPOCK) website at http://www.hp.com/storage/spock You must sign up for an HP Passport to be granted access. Supported HBAs For a list of HBAs that have been tested and are known to work with the SAN switches, see the HP StorageWorks Single Point of Connectivity Knowledge (SPOCK) website at http://www.hp.com/storage/spock. You must sign up for an HP Passport to be granted access. 32 A Technical Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

32
A Technical Specifications
Weight and physical dimensions
Table 7
lists physical properties.
Table 7
Physical dimensions
Environmental requirements
To ensure proper operation, the switch must not be subjected to environmental conditions beyond those
for which it was tested. The ranges specified in
Table 8
on page 32 list the acceptable environment for
both operating and non-operating conditions.
Table 8
Environmental requirements
Supported SFPs
Do not use unsupported SFPs; they can affect switch operability. They may not fit correctly and may void
your warranty. See ”
Optional hardware
” on page 10 for a list of supported SFPs.
For a complete list of supported devices, see the HP StorageWorks Single Point of Connectivity
Knowledge (SPOCK) website at
You must sign up for an HP Passport to be granted access.
Supported HBAs
For a list of HBAs that have been tested and are known to work with the SAN switches, see the HP
StorageWorks Single Point of Connectivity Knowledge (SPOCK) website at
You must sign up for an HP Passport to be granted access.
Dimension
Measurement
Height
29.3 mm (1.15 in)
Width
208 mm (8.19 in)
Depth
280 mm (11.02 in)
Weight
1.27 kg (2.8 lb)
Condition
Acceptable range during operation
Acceptable range during
non-operation
Ambient temperature
104°F/40°C at sea level, derated
34°F/1°C per 1000 ft above sea
level
-40°F/-40°C to 58°F/70°C with
maximum rate of change of
68°F/20°C /hr
Humidity
5% to 90% relative humidity,
non-condensing
50% to 80% relative humidity,
non-condensing
Altitude
0 to 10,000 ft (3 km) above sea
level
0 to 40,000 ft (12 km) above sea
level
Shock
40 G, 2mS duration
140 G, 2mS duration
Vibration
0.5 G, 10 to 500 Hz
2.0 G, 5 to 500 Hz
Airflow
47 cubic ft per minute
None required