HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 14
PSR fetch failure. Probable Cause: SFW tried to read the Processor Status Register
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Event ID Event Severity Event Description 5040 Error Could not allocate memory for EFI image. Probable Cause: SFW could not allocate enough memory for EFI image. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 217. WBEM ProviderName: FPL_IndicationProvider 5041 Error EFI image corrupted. Probable Cause: EFI image is corrupted. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 218. WBEM ProviderName: FPL_IndicationProvider 5042 Error EFI not in fit table. Probable Cause: EFI image is not in FIT. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 219. WBEM ProviderName: FPL_IndicationProvider 5045 Error NVRAM test fail. Probable Cause: NVM is corrupted or bad. Recommended Action: Clear NVM, if problem persists contact your HP representative for support. WBEM EventID: 220. WBEM ProviderName: FPL_IndicationProvider 5048 Error EFI Rom size bad. Probable Cause: EFI image is corrupt. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 221. WBEM ProviderName: FPL_IndicationProvider 5049 Error EFI Rom checksum error. Probable Cause: EFI image is corrupt. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 222. WBEM ProviderName: FPL_IndicationProvider 5050 Error External interruption nest limit exceeded. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 223. WBEM ProviderName: FPL_IndicationProvider 5051 Error External interrupt not serviced. Probable Cause: Internal FW error. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 224. WBEM ProviderName: FPL_IndicationProvider 5052 Error Ext int taken. Probable Cause: An external interrupt has been taken Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 225. WBEM ProviderName: FPL_IndicationProvider 5053 Warning Forward Progress Log (FPL) access failed. Probable Cause: FPL access has failed, possibly due to BMC communication interruption. SFW will not send any events to the FPL until the system is rebooted. Recommended Action: Reboot or update System and BMC FW. If problem persists contact your HP representative for support. WBEM EventID: 226. WBEM ProviderName: FPL_IndicationProvider 5054 Error PSR fetch failure. Probable Cause: SFW tried to read the Processor Status Register before the CPU data structure has been setup. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 227. WBEM ProviderName: FPL_IndicationProvider 5055 Error Cell halt. Probable Cause: Internal Error Recommended Action: contact your HP representative for support. WBEM EventID: 228. WBEM ProviderName: FPL_IndicationProvider 5056 Warning CPU PAL incompatible with cpu. Probable Cause: Incompatible PAL. Recommended Action: Update SFW or change processors WBEM EventID: 229. WBEM ProviderName: FPL_IndicationProvider 5057 Warning Slave is incompatible with monarch. Probable Cause: Incompatible processors. Recommended Action: Replace processors. WBEM EventID: 230. WBEM ProviderName: FPL_IndicationProvider 5058 Warning Interrupt clear failure. Probable Cause: Interrupt clear failed. Recommended Action: Reboot, if problem persists contact your HP representative for support. WBEM EventID: 231. WBEM ProviderName: FPL_IndicationProvider 5059 Warning System Event Log (SEL) access failed. Probable Cause: An IPMI event has failed. Recommended Action: Reset the BMC and reboot. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 232. WBEM ProviderName: FPL_IndicationProvider 14 WBEM Provider Event Tables