HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 67
PDC failed to read the HV Flag in the Partition Configuration Data. Probable Cause
![]() |
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Event ID Event Severity Event Description 9682 Warning Firmware unable to relocate VGA BIOS. Probable Cause: Most likely there is a permanent memory error in the VGA BIOS region (physical address 0xc0000 - 0xdffff). Recommended Action: Replace the DIMM causing the permanent memory error in the VGA BIOS region. The PDT reports which DIMM is causing errors in the physical address range 0xc0000 - 0xdffff. WBEM EventID: 986. WBEM ProviderName: FPL_IndicationProvider 9685 Error The Compatibility Matrix stored in NVRAM has a checksum error. Probable Cause: NVRAM has become corrupt. Restore from a backup. WBEM EventID: 987. WBEM ProviderName: FPL_IndicationProvider 9695 Error PDC failed its attempt to get default RDR values. Probable Cause: Hardware problem with the CPU. Recommended Action: Contact HP Support to confirm the CPU is functioning properly. WBEM EventID: 1811. WBEM ProviderName: FPL_IndicationProvider 9696 Error PDC could not read current RDR values of the executing CPU. Probable Cause: Hardware problem with the CPU. Recommended Action: Contact HP Support to confirm the CPU is functioning properly. WBEM EventID: 1812. WBEM ProviderName: FPL_IndicationProvider 9697 Error PDC failed reading a specific value from its own copy of the RDRs. Probable Cause: problem on cell wherein PDC could not properly access memory Recommended Action: Contact HP support to troubleshoot cell board. Probable Cause: a non-existent/non-accessible register was specified by software. Recommended Action: Contact HP support for possible PDC upgrade WBEM EventID: 1813. WBEM ProviderName: FPL_IndicationProvider 9698 Error PDC failed reading a specific value from its own copy of the RDRs. Probable Cause: problem on cell wherein PDC could not properly access memory Recommended Action: Contact HP support to troubleshoot cell board WBEM EventID: 1814. WBEM ProviderName: FPL_IndicationProvider 9700 Error PDC failed attempting to update ZLCO and PREFETCH RDR settings. Probable Cause: Could not update CPU settings Recommended Action: Contact HP support to troubleshoot cell board and CPU. WBEM EventID: 1815. WBEM ProviderName: FPL_IndicationProvider 9701 Error PDC failed to read the HV Flag in the Partition Configuration Data. Probable Cause: An error occurred which prevented the complex profiles from being distributed properly. Recommended Action: Create and distribute a new complex profile using ParMgr on a functional partition in the complex. Restore the last complex profile using the 'CC' command from the MP, then use ParMgr to create a new complex profile. Generate a genesis complex profile using the 'CC' command from the MP, then use ParMgr to create a new complex profile. WBEM EventID: 1816. WBEM ProviderName: FPL_IndicationProvider 9706 Warning Failed to get the configured set from the Complex Profiles A and C. Probable Cause: A hardware problem exists with MP or PDHC hardware. Recommended Action: Contact HP Support to confirm the MP and PDHC are functioning properly. WBEM EventID: 993. WBEM ProviderName: FPL_IndicationProvider 9707 Warning No possible core cells were found in the configured set. Probable Cause: most likely a configuration problem, Recommended Action: check to ensure a valid core cell is configured to be in the partition. WBEM EventID: 994. WBEM ProviderName: FPL_IndicationProvider 9708 Warning Could not find a viable core cell in the partition. Probable Cause: Configuration error, fabric failure; the intended core cell failed during boot. Recommended Action: check partition configuration, check for failed cells. WBEM EventID: 995. WBEM ProviderName: FPL_IndicationProvider 9709 Warning Could not find a viable core cell in the partition. Probable Cause: Configuration error, Mainbackplane failure, The intended core cell failed during boot. Recommended Action: Check partition configuration, Check for failed cells, as indicated by high-alert level IPMI events earlier in the boot. WBEM EventID: 996. WBEM ProviderName: FPL_IndicationProvider Platform Events 67
![](/manual_guide/products/hewlettpackard-integrity-superdome-sx1000-hp-insight-manager-wbem-provider-events-reference-c05d679/67.png)