HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 65
An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Event ID Event Severity Event Description 9486 Error The system firmware had an error with the structured error handling mechanism. Probable Cause: Either there is an error in the system firmware or the system firmware has exhausted all resources. Recommended Action: Invalidate NVM or check for newer version of system firmware. WBEM EventID: 963. WBEM ProviderName: FPL_IndicationProvider 9487 Error Not enough malloc resources for I/O structure error handling. Probable Cause: Either invalidate NVM or check for a new version of system firmware. WBEM EventID: 964. WBEM ProviderName: FPL_IndicationProvider 9488 Error Unable to create entry for I/O structure error handling. Probable Cause: This is a system firmware error, either invalidate NVM or check for a newer version of system firmware. WBEM EventID: 965. WBEM ProviderName: FPL_IndicationProvider 9489 Error Unable to bind services for I/O structure exception handling. Probable Cause: This is a system firmware error. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 966. WBEM ProviderName: FPL_IndicationProvider 9490 Error Error initializing the I/O structure exception handling services. Probable Cause: This is a system firmware error. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 967. WBEM ProviderName: FPL_IndicationProvider 9491 Error Error initializing structured I/O exception data structures. Probable Cause: This is a system firmware error, there is a conflict with system resources. Either reset NVM or check for a newer version of system firmware. WBEM EventID: 968. WBEM ProviderName: FPL_IndicationProvider 9492 Error The I/O exception context has an error. Probable Cause: This is a system firmware error. Reset the system, invalidate NVM and reset the system, or check for a newer version of the system firmware. WBEM EventID: 969. WBEM ProviderName: FPL_IndicationProvider 9493 Error Error creating the internal data and services for the SBA. Probable Cause: This is a system firmware error. Reset the system; invalidate NVM and reset the system; or check for a newer version of system firmware. WBEM EventID: 970. WBEM ProviderName: FPL_IndicationProvider 9494 Error Error attaching the services to the SBA internal data structures. Probable Cause: This is a system firmware error. Reset the partition; invalidate NVM on the reporting cell and reset the system; or check for a newer version of system firmware. WBEM EventID: 971. WBEM ProviderName: FPL_IndicationProvider 9495 Error Error initializing the internal SBA data and services. Probable Cause: This is a system firmware error. Reset the partition; invalidate NVM on the reporting cell and reset the partition; or check for newer system firmware. WBEM EventID: 972. WBEM ProviderName: FPL_IndicationProvider 9496 Error The SBA type is unknown to the system firmware. Probable Cause: This is either a system firmware error, or the wrong I/O is connected to the system. Validate the system recipe both firmware and hardware. WBEM EventID: 973. WBEM ProviderName: FPL_IndicationProvider 9497 Warning An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified by the physical location. WBEM EventID: 974. WBEM ProviderName: FPL_IndicationProvider 9498 Warning Fabric link route around failed because the route around port was bad. Probable Cause: 2 or more XBC links are not routable. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane, CCs, etc WBEM EventID: 975. WBEM ProviderName: FPL_IndicationProvider 9652 Warning Predictive Failure in Memory. Probable Cause: You will receive this message if the memory system is observing a lot of corrected ECC errors from a DIMM. The specified DIMM may need to be serviced. Recommended Action: Contact your HP support representative to check the affected hardware. WBEM EventID: 1805. WBEM ProviderName: FPL_IndicationProvider Platform Events 65