HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 52
Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Event ID Event Severity Event Description 8646 Error Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add OLA cell's PDT to the partition PDT. Error accessing PDH space. Check fabric connection between OLA cell and core cell. Recommended Action: Gather IPMI event logs and contact HP Support. WBEM EventID: 6959. WBEM ProviderName: FPL_IndicationProvider 8647 Warning Attempt to update the cell map to include the OLA Cell failed. Probable Cause: Unable to write registers on the CC. Check cell board and system fabric. Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6960. WBEM ProviderName: FPL_IndicationProvider 8648 Error Fabric Discovery could not initialize the local cell's XBC link. Probable Cause: CC to XBC link init failure. Recommended Action: check CC, XBC, reset cell, reset backplane WBEM EventID: 756. WBEM ProviderName: FPL_IndicationProvider 8652 Error Internal firmware programming error. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 760. WBEM ProviderName: FPL_IndicationProvider 8676 Error Error writing the XIN init disable register. Probable Cause: Check XBC, CC, backplane WBEM EventID: 771. WBEM ProviderName: FPL_IndicationProvider 8677 Error Error reading the XIN init state register. Probable Cause: Check XBC, CC, backplane WBEM EventID: 772. WBEM ProviderName: FPL_IndicationProvider 8679 Error intermittent failure while retrying the CC to XBC link init. Probable Cause: contact your HP service representative WBEM EventID: 773. WBEM ProviderName: FPL_IndicationProvider 8690 Warning Initialization of a PCI node in the firmware device tree failed. Probable Cause: The PCI component could not create a device tree node. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. WBEM EventID: 774. WBEM ProviderName: FPL_IndicationProvider 8691 Error An error was encountered while scanning the PCI bus. Probable Cause: The PCI component experienced an internal system firmware error while scanning the PCI bus. Recommended Action: This is an internal system firmware error. Update system firmware or contact a system firmware representative. WBEM EventID: 775. WBEM ProviderName: FPL_IndicationProvider 8692 Warning An error was encountered initializing the PCI bridge. Probable Cause: The PCI component could not initialize a P2P bridge registers, probably due to faulty hardware. Recommended Action: Reseat or replace the PCI bridge card. WBEM EventID: 776. WBEM ProviderName: FPL_IndicationProvider 8693 Warning An error was encountered initializing the PCI IO map. Probable Cause: The PCI component had insufficient IO port space resources to support the installed PCI cards. Recommended Action: Remove one or more PCI cards to reduce resource requirements; check for faulty cards that are requesting more resources than they need. WBEM EventID: 777. WBEM ProviderName: FPL_IndicationProvider 8694 Warning An error was encountered creating the PCI MMIO map. Probable Cause: The PCI component had insufficient MMIO space to support the installed cards. Recommended Action: Remove one or more PCI cards to reduce the MMIO requirements; check for a PCI card requesting more MMIO resources than it needs. WBEM EventID: 778. WBEM ProviderName: FPL_IndicationProvider 8709 Error There was an error initializing the SBA node. Probable Cause: An error was while initializing the SBA firmware structures Recommended Action: Correct any previous errors Invalidate NVM and reset replace the cell board WBEM EventID: 779. WBEM ProviderName: FPL_IndicationProvider 8710 Error There was an error discovering the SBA. Probable Cause: An error was discovered with the SBA during discovery Recommended Action: Correct any previous errors Replace the I/O backplane WBEM EventID: 780. WBEM ProviderName: FPL_IndicationProvider 52 WBEM Provider Event Tables