HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 54
Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on
![]() |
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
Event ID Event Severity Event Description 8747 Error Firmware was unable to find a suitable block of main memory to relocate ROM. Probable Cause: Probably caused by lots of PDT entries, or no main memory present. WBEM EventID: 1036. WBEM ProviderName: FPL_IndicationProvider 8752 Warning Cell started OLA but is not configured in the complex profile of the partition. Probable Cause: Cell was issued an OLA command without first updating the complex profile to reflect its slot as configured in the partition. Recommended Action: Update the complex profile to include the new cell. WBEM EventID: 6955. WBEM ProviderName: FPL_IndicationProvider 8756 Error The Options service received an NVRAM allocation error. Probable Cause: Invalidate NVRAM and reset. WBEM EventID: 808. WBEM ProviderName: FPL_IndicationProvider 8757 Warning failure on OLA cell during attempt to synch its real-time clock. Probable Cause: Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6956. WBEM ProviderName: FPL_IndicationProvider 8758 Warning SAL errlog access timeout. Probable Cause: Firmware is taking too long to process requests. WBEM EventID: 810. WBEM ProviderName: FPL_IndicationProvider 8761 Warning The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 2442. WBEM ProviderName: FPL_IndicationProvider 8762 Warning Indicated the Dillon IPR is not cleared after a number of PDC attempts. Probable Cause: PDH FPGA IPR is not cleared after a number of PDC attempts. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 1759. WBEM ProviderName: FPL_IndicationProvider 8763 Error failed accessing the core cell RTC while synchronizing the OLA cell's RTC. Probable Cause: Core cell data could not be accessed/fabric connections went bad Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6957. WBEM ProviderName: FPL_IndicationProvider 8768 Warning The echelon given in the data field is not fully populated. Probable Cause: the specified echelon is not fully populated and is not usable Recommended Action: add or replace dimms in the specified echelon WBEM EventID: 816. WBEM ProviderName: FPL_IndicationProvider 8771 Warning Attempted to read the port state from an illegal port number. Probable Cause: An invalid port number has been provided. The port number will be converted to an internal port and processing should continue. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 817. WBEM ProviderName: FPL_IndicationProvider 8772 Warning Attempted to write the port state for an illegal port. Probable Cause: An invalid port number has been provided. The port number will be converted to an internal port and processing should continue. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 818. WBEM ProviderName: FPL_IndicationProvider 8784 Warning The main backplane is reporting the LPM status as fault. Probable Cause: Many possible causes, repair / replace the appropriate part. WBEM EventID: 1760. WBEM ProviderName: FPL_IndicationProvider 8787 Warning The IO backplane is reporting a LPM status as fault. Probable Cause: Service / replace the appropriate part of, or the entire backplane. WBEM EventID: 1762. WBEM ProviderName: FPL_IndicationProvider 8797 Error System firmware was unable to default the complex profile. Probable Cause: Needed information could not be obtained. Reset the MP. WBEM EventID: 822. WBEM ProviderName: FPL_IndicationProvider 54 WBEM Provider Event Tables
![](/manual_guide/products/hewlettpackard-integrity-superdome-sx1000-hp-insight-manager-wbem-provider-events-reference-c05d679/54.png)