HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 46
Probable Cause: Probable Either System firmware or PDHC Firmware on the named
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Event ID Event Severity Event Description 7880 Error System Backplane voltage margin failed. Probable Cause: The CLU was unable to write to the voltage margin register on the System backplane. Recommended Action: Try re-margining the system backplane and check connections. If many I2C access events are occurring inspect the UGUY utilities board. WBEM EventID: 700. WBEM ProviderName: FPL_IndicationProvider 7891 Warning Failure to write data to FRUID EEPROM. Probable Cause: The entity being written to has failed. Recommended Action: Replace the entity with the failed FRUID. WBEM EventID: 701. WBEM ProviderName: FPL_IndicationProvider 7892 Error CPU fan failed. Probable Cause: The CPU fan identified by the attached physical location has failed. Recommended Action: Contact HP Support personnel to troubleshoot problem WBEM EventID: 2904. WBEM ProviderName: FPL_IndicationProvider 7893 Warning CPU fan failing. Probable Cause: The CPU fan identified by the attached physical location is not operating at expected speed. Recommended Action: Contact HP Support personnel to troubleshoot problem WBEM EventID: 2905. WBEM ProviderName: FPL_IndicationProvider 7894 Error CC chip fan failed. Probable Cause: The CC chip fan identified by the attached physical location has failed. Recommended Action: Contact HP Support personnel to troubleshoot problem WBEM EventID: 2906. WBEM ProviderName: FPL_IndicationProvider 7895 Warning CC chip fan failing. Probable Cause: The CC chip fan identified by the attached physical location is not operating at expected speed. Recommended Action: Contact HP Support personnel to troubleshoot problem WBEM EventID: 2907. WBEM ProviderName: FPL_IndicationProvider 7896 Error System FW and the PDHC have incompatible shared memory interface revisions. Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named cell was upgraded to a new major revision number and not the other. The major numbers must match when checked by the PDHC or else the cell will not be allowed to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event log. Compare to other cells in the complex, or, if single cell, check firmware revs. available to FWUU. WBEM EventID: 4954. WBEM ProviderName: FPL_IndicationProvider 7902 Error PDH Controller firmware version is not supported with this version of MP FW. Probable Cause: PDH Controller firmware version is not supported with this version of MP FW Recommended Action: Update PDHC or MP firmware WBEM EventID: 707. WBEM ProviderName: FPL_IndicationProvider 7903 Error Power fault on cell board. Probable Cause: One or more of the DC to DC power converters on the Cell Power Board is displaying a fault condition. Recommended Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 708. WBEM ProviderName: FPL_IndicationProvider 7938 Warning The CPU Node reported a problem initializing its node in the device tree. Probable Cause: See additional logs in determine why initialize node failed. There could be a hardware or PAL problem. WBEM EventID: 2437. WBEM ProviderName: FPL_IndicationProvider 7939 Warning The ExecuteCommand function failed on a CPU. Probable Cause: Inter-Processor-Interrupts may not be working, or the command may have timed out. This could be a firmware bug or hardware problem. Look for other clues in the event log. WBEM EventID: 710. WBEM ProviderName: FPL_IndicationProvider 7940 Warning A remote CPU is not prepared to receive a command. Probable Cause: The CPU may be stuck waiting for a previous command or may not be healthy. This could also be caused by a system resource contention problem. WBEM EventID: 711. WBEM ProviderName: FPL_IndicationProvider 7948 Warning An error was encountered when executing a PAL_PROC. Probable Cause: PAL was unable to be successfully called. See other event ids to determine if action needs to be taken. WBEM EventID: 614. WBEM ProviderName: FPL_IndicationProvider 46 WBEM Provider Event Tables