HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 43
Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Event ID Event Severity Event Description 7796 Warning 1 Side Converter Over Temp. Probable Cause: If this code is not accompanied by other codes pointing to the same Bulk Power Supply, then it is an internal component failure. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 2436. WBEM ProviderName: FPL_IndicationProvider 7798 Warning Bulk Power Supplies are not Redundant. Probable Cause: Entities were added to the cabinet, increasing the estimated Power Consumption. Or, a non-functional GSP bus entity has become functional, providing previously missing power consumption information. Recommended Action: Purchase and install a Bulk Power Supply, if redundancy is desired. WBEM EventID: 659. WBEM ProviderName: FPL_IndicationProvider 7799 Error +48V DC has exceeded its upper limit. Probable Cause: The cabinet's 48V power has exceeded an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 660. WBEM ProviderName: FPL_IndicationProv 7803 Error +48V DC has fallen below its lower limit. Probable Cause: The cabinet's 48V power has fallen below an acceptable lower threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 661. WBEM ProviderName: FPL_Indica 7806 Warning Cabinet Fan Failed. Probable Cause: Cabinet Fan Failed Recommended Action: Replace failed cabinet fan module as soon as possible following the Cabinet Fan Module Remove and Replace Procedures. WBEM EventID: 662. WBEM ProviderName: FPL_IndicationProvider 7822 Error Housekeeping power has exceeded expected levels. Probable Cause: The cabinet's housekeeping power has risen above an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 670. WBEM ProviderName: FPL_IndicationProvider 7823 Error Housekeeping power has fallen below expected levels. Probable Cause: The cabinet's housekeeping power has fallen below an acceptable upper threshold. Recommended Action: Contact HP Support personnel to troubleshoot problem. WBEM EventID: 671. WBEM ProviderName: FPL_IndicationProvider 7824 Warning The BPSs for the cabinet are illegally configured. Data Byte 3 = PDCA number. Probable Cause: The BPS are installed in an illegal configuration. Recommended Action: Re-configure the BPS in a manner consistent with the explanation in the Problem Description statement WBEM EventID: 672. WBEM ProviderName: FPL_IndicationProvider 7825 Warning BPS ID received from installed Bulk Power Supply was unknown. Probable Cause: The designated power supply is responding with an illegal BPS ID. It could be a faulty supply, a different revision, or a wrong supply in the wrong box. Recommended Action: Replace this Bulk Power Supply with a proper one. WBEM EventID: 673. WBEM ProviderName: FPL_IndicationProvider 7827 Error Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature has risen to a critical level. Recommended Action: Shutdown and power off the system. Correct air temperature problem. WBEM EventID: 675. WBEM ProviderName: FPL_IndicationProvider 7828 Warning Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature is rising or falling. Recommended Action: Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved. WBEM EventID: 676. WBEM ProviderName: FPL_IndicationProvider 7829 Error Ambient Air Sensor Overtemp Warning. Probable Cause: Room Temperature is rising or falling. Recommended Action: Check the error log's previous entries within a logical time frame. If temperature is rising, prepare for system shutdown. If temperature is dropping, then problem is probably resolved. WBEM EventID: 677. WBEM ProviderName: FPL_IndicationProvider Platform Events 43