HP Integrity Superdome SX1000 HP Insight Manager WBEM Provider Events Referenc - Page 57

Could not initialize the CC to CC link upon boot. Probable Cause: CC CSR Access

Page 57 highlights

Event ID Event Severity Event Description 8895 Warning Failed to write the CC link disable register. Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 853. WBEM ProviderName: FPL_IndicationProvider 8896 Warning An unknown backplane type was found. Probable Cause: CSR Read/Write error Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 854. WBEM ProviderName: FPL_IndicationProvider 8897 Warning Error writing the CC link error mask. Probable Cause: Fabric Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 855. WBEM ProviderName: FPL_IndicationProvider 8898 Warning Failed to read the CC's fabric link error mask. Probable Cause: CC CSR access failure. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 856. WBEM ProviderName: FPL_IndicationProvider 8900 Error Could not initialize the CC to CC link upon boot. Probable Cause: CC CSR Access Failure. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 857. WBEM ProviderName: FPL_IndicationProvider 8906 Warning An Error occurred trying to notify the MP of the attempted reset. Probable Cause: The MP is not functioning or the PDHC cannot communicate with it. Reset the MP. WBEM EventID: 858. WBEM ProviderName: FPL_IndicationProvider 8926 Warning Failed disabling the XIN link for a single cell model. Probable Cause: Fabric Access Error. Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM EventID: 860. WBEM ProviderName: FPL_IndicationProvider 8930 Error Error while getting the XBC Semaphore. Probable Cause: Most likely a hardware problem, but confirm the cause by looking at the return status. Recommended Action: Check XBC, Backplane, Flex Cables, Contact HP Support Personnel for further troubleshooting. WBEM EventID: 861. WBEM ProviderName: FPL_IndicationProvider 8931 Warning Error releasing the XBC Semaphore. Probable Cause: Fabric Access problem. Either an error reading the hardware or XBC Key contention. Recommended Action: Look for additional chassis codes to provide detail. Check XBC, Backplane, Flex Cables, Contact HP Support Personnel. WBEM EventID: 862. WBEM ProviderName: FPL_IndicationProvider 8936 Warning Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred. Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 864. WBEM ProviderName: FPL_IndicationProvider 8939 Warning The CC's XIN link was found to be already initialized. Probable Cause: Firmware problem. Contact HP Support Personnel. WBEM EventID: 865. WBEM ProviderName: FPL_IndicationProvider 8940 Error Cell has been disabled by the PDHC because no CPU modules were found. Probable Cause: No CPU modules are installed. Recommended Action: Install CPU modules on the Cell. WBEM EventID: 866. WBEM ProviderName: FPL_IndicationProvider 8941 Error Cell has been disabled by PDHC FW because the CPU modules are not compatible. Probable Cause: At least one of the installed CPU modules are incompatible with at least one other CPU module. Recommended Action: Contact HP support personnel to troubleshoot the CPU modules on the Cell. WBEM EventID: 867. WBEM ProviderName: FPL_IndicationProvider 8942 Error Cell has been disabled because of invalid data in a CPU module Scratch EEPROM. Probable Cause: The CPU module is not an HP CPU module, or the FRUID data for this CPU module has not been programmed. Recommended Action: Contact HP support personnel to troubleshoot the CPU module. WBEM EventID: 868. WBEM ProviderName: FPL_IndicationProvider 8954 Warning The Cell Battery voltage level low warning. Probable Cause: The Cell Battery is low. Recommended Action: It needed to be replaced. WBEM EventID: 869. WBEM ProviderName: FPL_IndicationProvider Platform Events 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

Event Description
Event Severity
Event ID
Failed to write the CC link disable register. Probable Cause: Fabric Access Failure.
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 853. WBEM ProviderName: FPL_IndicationProvider
Warning
8895
An unknown backplane type was found. Probable Cause: CSR Read/Write error
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 854. WBEM ProviderName: FPL_IndicationProvider
Warning
8896
Error writing the CC link error mask. Probable Cause: Fabric Access Error.
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 855. WBEM ProviderName: FPL_IndicationProvider
Warning
8897
Failed to read the CC's fabric link error mask. Probable Cause: CC CSR access failure.
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 856. WBEM ProviderName: FPL_IndicationProvider
Warning
8898
Could not initialize the CC to CC link upon boot. Probable Cause: CC CSR Access
Failure. Recommended Action: Contact HP Support personnel to analyze the fabric.
WBEM EventID: 857. WBEM ProviderName: FPL_IndicationProvider
Error
8900
An Error occurred trying to notify the MP of the attempted reset. Probable Cause:
The MP is not functioning or the PDHC cannot communicate with it. Reset the MP.
WBEM EventID: 858. WBEM ProviderName: FPL_IndicationProvider
Warning
8906
Failed disabling the XIN link for a single cell model. Probable Cause: Fabric Access
Error. Recommended Action: Contact HP Support personnel to analyze the fabric.
WBEM EventID: 860. WBEM ProviderName: FPL_IndicationProvider
Warning
8926
Error while getting the XBC Semaphore. Probable Cause: Most likely a hardware
problem, but confirm the cause by looking at the return status. Recommended Action:
Check XBC, Backplane, Flex Cables, Contact HP Support Personnel for further
troubleshooting. WBEM EventID: 861. WBEM ProviderName: FPL_IndicationProvider
Error
8930
Error releasing the XBC Semaphore. Probable Cause: Fabric Access problem. Either
an error reading the hardware or XBC Key contention. Recommended Action: Look
for additional chassis codes to provide detail. Check XBC, Backplane, Flex Cables,
Contact HP Support Personnel. WBEM EventID: 862. WBEM ProviderName:
FPL_IndicationProvider
Warning
8931
Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 864.
WBEM ProviderName: FPL_IndicationProvider
Warning
8936
The CC's XIN link was found to be already initialized. Probable Cause: Firmware
problem. Contact HP Support Personnel. WBEM EventID: 865. WBEM ProviderName:
FPL_IndicationProvider
Warning
8939
Cell has been disabled by the PDHC because no CPU modules were found. Probable
Cause: No CPU modules are installed. Recommended Action: Install CPU modules
on the Cell. WBEM EventID: 866. WBEM ProviderName: FPL_IndicationProvider
Error
8940
Cell has been disabled by PDHC FW because the CPU modules are not compatible.
Probable Cause: At least one of the installed CPU modules are incompatible with at
least one other CPU module. Recommended Action: Contact HP support personnel
to troubleshoot the CPU modules on the Cell. WBEM EventID: 867. WBEM
ProviderName: FPL_IndicationProvider
Error
8941
Cell has been disabled because of invalid data in a CPU module Scratch EEPROM.
Probable Cause: The CPU module is not an HP CPU module, or the FRUID data for
this CPU module has not been programmed. Recommended Action: Contact HP
support personnel to troubleshoot the CPU module. WBEM EventID: 868. WBEM
ProviderName: FPL_IndicationProvider
Error
8942
The Cell Battery voltage level low warning. Probable Cause: The Cell Battery is low.
Recommended Action: It needed to be replaced. WBEM EventID: 869. WBEM
ProviderName: FPL_IndicationProvider
Warning
8954
Platform Events
57