HP LH4r HP Netserver LH 3 NetRAID-3Si Installation Guide - Page 6

Storage

Page 6 highlights

System software: Navigator version Operating System Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage L.15.15 or later (350-450 MHz with 40 MB/Sec SCSI controller board) L.16.00 or later (400 or 450 MHz with 80 MB/Sec SCSI controller board) L.16.05 or later (500, 550, 600 MHz with 40 MB/Sec SCSI controller board) Microsoft Windows NT Server 4.0, Enterprise Edition or later SP4 or later HP NetServer LH3 350, 400, 450 MHz with Rack Storage/12 D5989A 400, 450, 500, 550, 600 MHz with Rack Storage/12 D5989B 2 4.06.28PL or later (350-450 MHz with Rack Storage/12 D5989A) 4.06.14PL or later (400 or 450 MHz with Rack Storage/12 D5989B) 4.06.33PL or later (400, 450, 500, 550, 600 with Rack Storage/12 D5989B Any size 128 MB minimum. Must be HP. 2 required, 3 for redundancy Internal or external, using any controller except embedded RAID or a NetRAID-3Si. Must use HP disks. See Local Storage below. P7 - P8 Shared storage controller P1 - Intra-cluster (Heartbeat) LAN P2 - Client LAN All others - Any other plug-in cards. Local Controller and Cabinets (physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI IDs May use Embedded SCSI, NetRAID 1 or NetRAID 3 in PCI slot P8 for internal storage or with a Rack Storage/8, otherwise any controller listed on the HP Tested Products List. May not use Embedded RAID, NetRAID-1Si or NeRAID-3Si for internal storage or external with a Rack Storage/12. HP only Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID Channels HP NetRAID-3Si Adapter D5955A 1 W.01.20 or later B.01.10 or later 2.22 or later A.01.15 or later P7 - P8 6, 7 0, 1, 2 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

2
System software:
Navigator version
L.15.15 or later (350-450 MHz with 40 MB/Sec SCSI controller board)
L.16.00 or later (400 or 450 MHz with 80 MB/Sec SCSI controller board)
L.16.05 or later (500, 550, 600 MHz with 40 MB/Sec SCSI controller board)
Operating System
Microsoft Windows NT Server 4.0, Enterprise Edition or later
Service pack
SP4 or later
SPU
Model
HP NetServer LH3
Clock speed
350, 400, 450 MHz with Rack Storage/12 D5989A
400, 450, 500, 550, 600 MHz with Rack Storage/12 D5989B
No. of CPUs
2
BIOS version
4.06.28PL or later (350-450 MHz with Rack Storage/12 D5989A)
4.06.14PL or later (400 or 450 MHz with Rack Storage/12 D5989B)
4.06.33PL or later (400, 450, 500, 550, 600 with Rack Storage/12 D5989B
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
2 required, 3 for redundancy
Local storage
Internal or external, using any controller except embedded RAID or a
NetRAID-3Si. Must use HP disks.
See
Local Storage
below.
I/O slots:
P7 – P8 Shared storage controller
P1 – Intra-cluster (Heartbeat) LAN
P2 – Client LAN
All others – Any other plug-in cards.
Storage
Local
Controller and Cabinets
(physical drive location)
May use
Embedded SCSI, NetRAID 1 or NetRAID 3 in PCI slot P8 for
internal storage or with a Rack Storage/8, otherwise any controller listed
on the HP Tested Products List.
May not use
Embedded RAID, NetRAID-1Si or NeRAID-3Si for internal
storage or external with a Rack Storage/12.
Disk drives (hot swap
or fixed)
HP only
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.20 or later
BIOS
B.01.10 or later
Driver
2.22 or later
NetRAID Assistant
A.01.15 or later
SPU I/O slot
P7 - P8
SCSI ID
6, 7
Channels
0, 1, 2